Neurosurgeons have long sought a means of epidural measurement of intracranial pressure (ICP), but minute irregularities of the dural surface compromise accuracy when conventional transducers are used to measure epidural pressure (EDP). A silicone rubber-lined pressure transducer developed by the authors prevents the sensor diaphragm from being affected by outside temperature pressure is thus diffusely transmitted across the dural surface so as to diminish stress buildup.<BR>It has been found from the output-depth curves of the experimental model that coplanar measurement minimized the pull of the transducer, and that the angle dependency was negligibly small. Thus, pout-pin curves approached those obtained by directly measuring the hydrostatic pressure. The EDP-IVP slope showed a 45° line with a slight deviation between animals and humans.<BR>The EDP transducer was used in 64 cases for a total of 5, 840 hrs, postoperatively. EDP values varied from zero to above 1, 000 mmH<SUB>2</SUB>O within 3 postoperative days. Besides changes in the basal level of EDP, sudden pressure oscillations, which were classified by Lundberg as A, B and C plateau waves, were observed.<BR>In the plateau wave of A type, EDP rose suddenly to 1, 000 mmH<SUB>2</SUB>O from its base line level, and lasted 5 to 20 minutes. However, variations of B type usually appeared as a rhythmic grouping. These waves were accompanied by hypopnea in the high EDP period, but by hyperpnea or tachypnea in the decreasing course of EDP. Depressed wakefulness in the patient was usually accompanied by B waves.<BR>From the present results, EDP measurement with our EDP transducer was found to be a safe, sure, easy, and extremely useful method for the clinical monitoring of ICP. It has been found that since ICP variations are usually associated with variation in blood pressure, respiration and the wakefulness of the patient, polygraphic observation will be necessary to understand the pathogenesis of ICP.
- 一般社団法人 日本生体医工学会の論文
一般社団法人 日本生体医工学会 | 論文
- Evaluating the Workload Reduction of Automatic Vital Data Transmission
- Mental Fatigue Measurement Based on the Changes in Flicker Perception Threshold using Consumer Mobile Devices
- A Theoretical Study on a Computational Algorithm for Human Posture Estimation Based on Motion Capture of a Small Number of Markers
- Latest microscopic technique. From the principle to application. Development of three-dimensional microscopic system for operation of mini-pig fertilized eggs.
- A Study of the Automation of Cytodiagnosis (The Second Report):Cytophotometry Using Photomicroscanner and a Trial of Data-processing