アルミニウムの糸状腐食
スポンサーリンク
概要
- 論文の詳細を見る
Filiform corrosion of A-1070 and pitting corrosion of A-1050 were investigated. Dipping tests and electrochemical measurements in 3wt%NaCl solution were carried out. A saturated calomel electrode as a reference electrode was used. Scanning electron microscopy on the sample surface was made. Filiform corrosion terminates after immersion for 120min. It is caused by slight dissolution of oxygen. A-1070 shows a lower corrosion rate than A-1050. Effective cathodic areas of A-1070 and A-1050 are caused by Fe and Cu of an impurity, respectively.