Continuous Monitoring of Chlorophenols in Flue Gas from Waste Incinerators by Liquid Chromatography, (I) Investigation of Sampling and Analytical Conditions, and Development of Sequential Automated Monitoring System with a Drain Condensation Trap
スポンサーリンク
概要
- 論文の詳細を見る
In order to analyze 11 compounds of dichlorophenols (Di-CPs) and trichlorophenols (Tri-CPs) in flue gas from waste incinerators by using a high performance liquid chromatograph (HPLC) with electrochemical detector (EChD), the collection efficiency with absorption solutions under different conditions, some kinds of the mobile phases with different pH for HPLC, or the different applied voltage for the detection were investigated. Then, the adequate conditions were determined for the analysis of CPs at 0.1-1000ng/m<SUP>3</SUP> in flue gas. In addition, six kinds of the pre-cut column/valves systems examined for continuous CPs analysis. Two types of the sequential full-automated analytical instrument were developed and the usefulness of these instruments was demonstrated in the actual test at waste incinerators. In this paper, the basic data and the experiences related with the analysis or the instruments are described.
- 日本環境化学会の論文
日本環境化学会 | 論文
- 廃棄物埋立地浸出水および処理水中の無機成分、ジオキサン、フェノール類およびフタル酸エステル類の濃度
- 有機スズ代替船底防汚剤による広島湾北部海域の底質汚染状況
- 広島湾北部における有機スズ代替船底防汚剤による海域の汚染状況について
- 難燃処理済スチレンポリマー中のポリ臭素化ジフェニルエーテルの溶媒抽出及び熱脱着 GC/MS 分析
- プレカラム分離導入システムを用いたダイオキシン類の測定