Demonstration of Dioxins-reduced Small Size Incinerator(Part 2).
スポンサーリンク
概要
- 論文の詳細を見る
In this study, removal efficiency and adsorption characteristics of dioxins (polychlorinated dibenzo-<I>p</I>-dioxins, polychlorinated dibenzofurans = PCDD/DF, and coplaner polychlorinated biphenyls) were investigated in activated alumina equipped in the exhaust gas line of small size incinerator. When model wastes containing 3 % polyvinyl chloride resin were incenerated, the concentrations of dioxins in the final treatment gas were 0.19 to 0.33 ng-TEQ/Nm<SUP>3</SUP>, which were adequately below the regulation (5 ng-TEQ/Nm<SUP>3</SUP>) . The removal rate was relatively high in higher chlorinated dioxin-congeners. Furthermore removal rates of acidic gas suches HCl, NO<SUB>x</SUB> and SO<SUB>2</SUB> were also relatively high. By these results, it was found that activated alumina, as well as artificial zeolite, was effective for the removal treatment of dioxins in exhaust gas.