Effect of different adhesives combined with two resin composite cements on shear bond strength to polymeric CAD/CAM materials
スポンサーリンク
概要
- 論文の詳細を見る
This study tested the impact of different adhesives and resin composite cements on shear bond strength (SBS) to polymethyl methacrylate (PMMA)- and composite-based CAD/CAM materials. SBS specimens were fabricated and divided into five main groups (n=30/group) subject to conditioning: 1. Monobond Plus/Heliobond (MH), 2. Visio.link (VL), 3. Ambarino P60 (AM), 4. exp. VP connect (VP), and 5. no conditioning-control group (CG). All cemented specimens using a. Clearfil SA Cement and b. Variolink II were stored in distilled water for 24 h at 37°C. Additionally, one half of the specimens were thermocycled for 5,000 cycles (5°C/55°C, dwell time 20 s). SBS was measured; data were analyzed using descriptive statistics, four- and one-way ANOVA, unpaired two-sample t-test and Chi2-test. CAD/CAM materials without additional adhesives showed no bond to resin composite cements. Highest SBS showed VL with Variolink II on composite-based material, before and after thermocycling.
著者
-
Gernet Wolfgang
Department Of Prosthodontics Ludwig-maximilians-university
-
Edelhoff Daniel
Department Of Prosthodontics Ludwig-maximilians-university
-
Roos Malgorzata
Division Of Biostatistics Institute Of Social And Preventive Medicine University Of Zurich
-
Stawarczyk Bogna
Department Of Prosthodontics Dental School Ludwig-maximilian University Of Munich
-
STAWARCZYK Bogna
Department of Prosthodontics, Dental School, Ludwig-Maximilians University Munich
-
KEUL Christine
Department of Prosthodontics, Munich Dental School, Ludwig-Maximilians University Munich
-
BÄHR Nora
Department of Prosthodontics, Dental School, Ludwig-Maximilians University Munich
-
EICHBERGER Marlis
Department of Prosthodontics, Dental School, Ludwig-Maximilians University Munich
関連論文
- Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system
- Effect of Preparation Design on the Fracture Resistance of Zirconia Crown Copings
- Fracture load and failure analysis of zirconia single crowns veneered with pressed and layered ceramics after chewing simulation
- Discoloration of manually fabricated resins and industrially fabricated CAD/CAM blocks versus glass-ceramic : Effect of storage media, duration, and subsequent polishing
- Tensile bond strength of veneering resins to PEEK: Impact of different adhesives
- Effect of different adhesives combined with two resin composite cements on shear bond strength to polymeric CAD/CAM materials
- Influence of cementation and cement type on the fracture load testing methodology of anterior crowns made of different materials
- Effect of different adhesives combined with two resin composite cements on shear bond strength to polymeric CAD/CAM materials
- Tensile bond strength of veneering resins to PEEK : Impact of different adhesives