Influence of filler on bite impression material in transillumination method for occlusal examination
スポンサーリンク
概要
- 論文の詳細を見る
The purpose of this present study was to investigate the influence of material filler and RGB values fluctuation on creating a calibration curve, which indicates the relationship between material thickness and transmitted light brightness using the transillumination method. Creating the calibration curves were carried out through the following three methods; 1) the conventional method creates the calibration curve with a formula of thickness, 2) the maximum value method, with samples of a specified thickness, and 3) the actual value method, with a microscope. Furthermore, the reliability of each curve was verified via scanned artificial tooth data. In addition, the characteristics of light decrement were investigated. From our results, it was suggested that the filler diameter must be considered when the calibration curve is created using the bite impression material with a filler. In addition, it was suggested that the RGB values fluctuation did not influence the calibration curve.
著者
-
Nikawa Hiroki
Department Of Medical Design And Engineering Division Of Oral Health Engineering Institute For Oral
-
Ogawa Takumi
Department Of Fixed Prosthodontics Tsurumi University School Of Dental Medicine
-
Ikawa Tomoko
Department Of Fixed Prosthodontics Tsurumi University School Of Dental Medicine
-
Shigeta Yuko
Department Of Fixed Prosthodontics Tsurumi University School Of Dental Medicine
-
Hirai Shinya
Department Of Fixed Prosthodontics Tsurumi University School Of Dental Medicine
-
Hirabayashi Rio
Department Of Fixed Prosthodontics Tsurumi University School Of Dental Medicine
-
Ando Eriko
Department Of Applied Chemistry And Biochemistry Graduate School Of Science And Technology Kumamoto University
-
SHIGETA Yuko
Department of Fixed Prosthodontics, School of Dental Medicine, Tsurumi University
-
ANDO Eriko
Department of Fixed Prosthodontics, School of Dental Medicine, Tsurumi University
-
KIHARA Takuya
Department of Oral Biology and Engineering, Division of Oral Health Sciences, Graduate School of Biomedical Sciences, Hiroshima University
-
OGAWA Takumi
Department of Fixed Prosthodontics, School of Dental Medicine, Tsurumi University
-
HIRAI Shinya
Department of Fixed Prosthodontics, School of Dental Medicine, Tsurumi University
関連論文
- Using the Digital Gothic Arch Tracer for Occlusal Diagnosis and Management of Malocclusion with Osteoarthritis
- Compatibility of tissue conditioners and denture cleansers : Influence on surface conditions
- Immobilization of Octadecyl Ammonium Chloride on the Surface of Titanium and Its Effect on Microbial Colonization In Vitro
- Titanium Surface Roughness Accelerates RANKL-dependent Differentiation in the Osteoclast Precursor Cell Line, RAW264.7
- Research Projects Related to Complete Dentures Published in 2006 by Members of the Japan Prosthodontic Society
- Diagnosis, Prevention and Management for Aspiration Pneumonia in Dental Practice
- The Establishment of the Snoring and OSA Clinic in Tsurumi UNIV. School of Dental Medicine
- New Bitter Diterpenes, Rabdosianone I and II, Isolated from Isodon japonicus Hara
- Research projects related to complete dentures published in 2008 by members of the Japan Prosthodontic Society
- Kinematic Analysis of Limitation of Mouth Opening of TMD by Rotation and Translation of Condyle
- Structure and CO Oxidation Activity of Pt/CeO_2 Catalysts Prepared Using Arc-Plasma
- Influence of filler on bite impression material in transillumination method for occlusal examination
- Influence of filler on bite impression material in transillumination method for occlusal examination
- Impact of titanium ions on osteoblast-, osteoclast-and gingival epithelial-like cells