Clinical study in optimal weaning condition of left ventricular assist device
スポンサーリンク
概要
- 論文の詳細を見る
LVAD was indicated in 9 patients for CPB weaning and in one patient for LOS after acute myocardial infarction, and 6 patients could wean off from LVAD. Weaning tests of LVAD were performed 23 times in these 6 cases. These weaning tests suggested that optimal weaning condition is pulmonary wedge pressure ≤18mmHg, cardiac index≥2.8l/min//m2 and left ventricular stroke work index≥27g·m/m2.