CONTINUOUS SvO2 MEASUREMENT DURING HEMODIALYSIS FOR ACUTE RENAL FAILURE FOLLOWING CARDIOVASCULAR SURGERY
スポンサーリンク
概要
- 論文の詳細を見る
Four patients with acute renal failure, after cardiovascular surgery were treated with hemodialysis (HD). Circulatory instability during HD is a main problem. Therefore we measured SvO2 continuously during HD as a predictor of change in cardiac output. In these of four patients, SvO2 values was higher than 65% before HD, but SvO2fell to less than 60% immediately after HD started. After 2 or 3 min-utes, hypotension was revealed. We conclude that in case of SvO2 rapidly decreased immediately after HD started, or decreased less than 60% during HD, careful manage-ment of fluid balance or use of catecholamine is necessary.
- 一般社団法人 日本人工臓器学会の論文
著者
-
相馬 民太郎
Department of Cardiovascular Surgery, Saiseikai Yokohama City Nanbu Hospital
-
岩井 芳弘
Department of Cardiovascular Surgery, Saiseikai Yokohama City Nanbu Hospital
-
坂本 哲
Department of Cardiovascular Surgery, Saiseikai Yokohama City Nanbu Hospital
-
鈴木 伸一
1st Dept of Surg, Yokohama City University
-
近藤 次郎
1st Dept of Surg, Yokohama City University
-
松本 昭彦
1st Dept of Surg, Yokohama City University