Perfect and Least Invasive Sealing Technique on the Lesser Curvature of the Aortic Arch: Application of a Novel Stent Graft to an Aneurysm Developing on a Postoperative Ductus Arteriosus
スポンサーリンク
概要
- 論文の詳細を見る
A 78-year-old woman who underwent an operation for a patent ductus arteriosus (PDA) about thirty years ago developed an aneurysm on the aortic side of the remnant ductal tissue. To avoid risky, open surgery, we performed endovascular aortic therapy using a novel stent graft (SG), which was pre-curved, fenestrated and custom-made type. This graft was designed to configure to the patient’s whole aortic arch anatomy, and was capable of accurately adjusting its fenestrations to the arch branch orifices during the procedure. The operation was successful, and the patient was discharged uneventfully on 16th postoperative day. The advantage of this fenestrated SG is close sealing, especially over the lesser curvature of the arch. This device could be a simple and effective option to deal with an otherwise normal aortic arch with such a ductus-related localized lesion.
著者
-
Soeda Takeshi
Department Of Applied Quantum Physics And Nuclear Engineering Kyushu University
-
Setozaki Shuji
Department Of Cardiovascular Surgery Matsue Red Cross Hospital
-
Harada Hisao
Department Of Cardiovascular Surgery Kyoto University
-
Yuri Koichi
Department Of Cardiovascular Surgery Saitama Medical Center Jichi Medical University
-
SAITO Yuuhei
Department of Cardiovascular Surgery, Matsue Red Cross Hospital
-
YOKOI Yoshihiko
Department of Cardiovascular Surgery, Tokyo Women's Medical University
-
Yuri Koichi
Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, Omiya, Saitama, Japan
-
Yokoi Yoshihiko
Department of Cardiovascular Surgery, Tokyo Women's Medical University, Tokyo, Japan
-
Soeda Takeshi
Department of Cardiovascular Surgery, Matsue Red Cross Hospital, Matsue, Shimane, Japan
関連論文
- 2 Endovascular Grafting for Distal Arch Thoracic Aortic Aneurysms with Fenestrated S.G.(Current Status and Future Prospective of Stent-gratting for Aortic Aneurysm,Meet the Expert 7 (ME-7) (H),The 73rd Annual Scientific Meeting of The Japanese Circulation
- 7 Endovascular Stent Grafting for Thoracic Aortic Aneurysms(Recent Progress in Diagnosis and Treatment of Aortic Diseases,Symposium 5 (SY-05) (A),The 73rd Annual Scientific Meeting of The Japanese Circulation Society)
- PJ-325 Midterm Results of Endografting for Abdominal Aortic Aneurysms : One Center Experience(Cardiovascular surgery/CABG-2, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- 4 Endovascular Stent Grafting for Thoracic Aortic Aneurysms : A New Technology of Minimally Invasive Treatment(Open surgery or Endovascular Repair for Aortic Aneurysm, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- PJ-506 Midterm Results of Endografting for Abdominal Aortic Aneurysms with Endologix Power Web System^(Cardiovascular surgery/CABG-2 (IHD) PJ85,Poster Session (Japanese),The 70th Anniversary Annual Scientific Meeting of the Japanese Circulation Societ
- Endovascular stent grafting for abdominal aortic aneurysm
- Endovascular Grafting for Various Conditions of Descending Thoracic Aorta
- Normal Values of Echocardiography in Pediatric Age Groups III. Left and Right Ventricular Systolic Time Intervals : The Shimane Heart Study
- Statistical Comparison of Echocardiographically Determined Left Ventricular Size Estimated by X-Y Digitizer System between Normotensive and Early Hypertensive Children : The Shimane Heart Study
- Basic Study for Computer Analysis of the Pediatric Electrocardiogram: Relation of the Distance-Corrected Precordial Electrocardiographic Voltage with the Echocardiographically Determined Left Ventricular Muscle Volume : Proceedings of the IV Conference on
- Relation of the Distance-Corrected Electrocardiographic and Vectorcardiographic Voltage with the Echocardiographically Determined Left Ventricular Muscle Volume : The Shimane Heart Study
- Quantitative electron diffraction study of cation configuration and irradiation induced displacement in magnesium aluminate spinel crystals
- Surgical Removal of an Accufix Pacing Lead With a Protruding J Wire
- Aortic Valve-sparing Operation and a Total Arch Replacement by an Elephant Trunk Method for Marfan's Syndrome with Aortic Regurgitation and a DeBakey Type IIIb Dissection
- Clinical Estimation of Left Ventricular Size : Precordial Electrocardiographic Voltage Corrected by the Measurement of Thorax : Proceedings of the 5th Conference on Prevention for Rheumatic Fever and Rheumatic Heart Disease
- Normal Value of the Interventricular Septal to Left Ventricular Posterior Wall Thickness Ratio Echocardiographic Determination in Normal Children and Adolescents : The Shimane Heart Study
- LEFT VENTRICULAR MUSCLE VOLUME AND FRACTIONAL SHORTENING OF LEFT VENTRICULAR DIMENSION BY ECHOCARDIOGRAPHY (DATA OBTAINED FROM MASS-SCREEENING OF SCHOOL CHILDREN) : Echocardiography I : IIIrd Auditorium : Proceedings of the 43rd Annual Meeting of the Japa
- Left Ventricular Hypertrophy in Early Hypertensive Children; Its Importance as a Risk Factor for Hypertension : The Shimane Heart Study
- Normal Values of Echocardiography in Pediatric Age Groups II. Per Cent Fractional Shortening of the Left Ventricular Dimension and Mean Velocity of Circumferential Fibre Shortening : The Shimane Heart Study
- Normal Values of Echocardiography in Pediatrics : I. Left Ventricular Muscle Volume (LVMV) : The Shimane Heart Study
- Serum Total Cholesterol Levels in Japanese Children : The Shimane Heart Study
- Echocardiographic Estimation of the Left Atrial/Aortic Root Ratio in Children with Ventricular Septal Defect and Atrial Septal Defect
- Aortic valve replacement for aortic regurgitation in a patient with antiphospholipid antibody syndrome
- Successful Treatment of an Abdominal Aortic Aneurysm by Endovascular Graft Placement Through a Previously Placed Prosthetic Graft : Report of a Case
- Development of the oxygenator : past, present, and future
- Mid-Term Outcomes After Aortic Valve Replacement With the 17-mm St. Jude Medical Regent Valve
- Clinical Outcomes and Hemodynamics of the 19-mm Perimount Magna Bioprosthesis in an Aortic Position : Comparison With the 19-mm Medtronic Mosaic Ultra Valve
- Perfect and Least Invasive Sealing Technique on the Lesser Curvature of the Aortic Arch: Application of a Novel Stent Graft to an Aneurysm Developing on a Postoperative Ductus Arteriosus
- Left Atrial Papillary Fibroelastoma Accidentally Diagnosed with Gastric Cancer
- Case Report: Successful Endovascular Treatment of Saccular Thoracic Aneurysm with "Shaggy Aorta"
- An innovative exclusion technique for ductus arteriosus with a novel stent graft
- Early aortic endograft failure in the presence of periaortic lymphadenopathy with neurofibromatosis (von Recklinghausen's disease)
- Reduction of Mitral Valve Leaflet Tethering by Procedures Targeting the Subvalvular Apparatus in Addition to Mitral Annuloplasty
- Successful Remodeling and Endovascular Repair of a Ruptured Type B Chronic Aortic Dissection 12 Years after Primary Surgery
- Stent-graft Implantation for Clinically Diagnosed Syphilitic Aortic Aneurysm in an HIV-infected Patient
- Bentall Operation for Prosthetic Valve Endocarditis with Hereditary Hemorrhagic Telangiectasia
- Case Report : Successful Endovascular Treatment of Saccular Thoracic Aneurysm with "Shaggy Aorta"
- Is the threshold for postoperative prosthesis-patient mismatch the same for all prostheses?