The Case of Long Lasting Septic Shock after the Removal of Infected ICD Generator and Lead
スポンサーリンク
概要
- 論文の詳細を見る
The case was 58 years old male. His chief complaints were fever and depressed consciousness. He had a history of aortic valve replacement on March 2006. On November 2010, we implanted ICD at the left subclavian space for treatment of sustained polymorphic VT. On the 15th day after operation he felt fever, and on the 17th day he became shock state with the deterioration of his consciousness, leading to the emergent admission of our hospital. His wound showed pus-discharge, so the extraction of his ICD generator and lead was performed on the second hospital day. But septic shock continued for 7 days with three types of antibiotics medication and drainage. The culture from his blood and wound showed Methycillin sensitive Staphylococcus aureus. The antibiotics change from Vancomycin to Ampicillin relieved his bacteremia and lowered fever on the 11th hospital day. On the 66th hospital day we newly implanted ICD system at the right subclavian space and on the 70th day he was discharged from our hospital.
著者
-
OGAWA Yasuhiro
The Department of Radiology,Kochi Medical School
-
Imai Hajime
The Department of Cardiology, Komaki City Hospital
-
Kondo Taizo
The Department of Cardiology, Komaki City Hospital
-
Sugiura Yuki
The Department of Cardiology, Komaki City Hospital
-
Nishikimi Miya
The Department of Cardiology, Komaki City Hospital
-
Fujii Noriaki
The Department of Cardiology, Komaki City Hospital
-
Kanoh Naoaki
The Department of Cardiology, Komaki City Hospital
-
Kamimura Yoshihiro
The Department of Cardiology, Komaki City Hospital
-
Funabiki Junya
The Department of Cardiology, Komaki City Hospital
-
Kawaguchi Katsuhiro
The Department of Cardiology, Komaki City Hospital
関連論文
- Tamoxifen-induced nonalcoholic steatohepatitis in breast cancer patients treated with adjuvant tamoxifen
- The Case of Long Lasting Septic Shock after the Removal of Infected ICD Generator and Lead