Intrathoracic Fluid Monitoring System (OptiVol) Proved Useful for Earlier Detection of Heart Failure (HF) and Asymptomatic Electrical Storm of Slow VT: A Case Report
スポンサーリンク
概要
- 論文の詳細を見る
We report a case of 78-year-old man with dilated form of hypertrophic cardiomyopathy. An ICD (Secura, Medtronic Inc.) was implanted for drug-resistant ventricular tachycardia (VT). He received remote home monitoring system (CareLink) including intrathoracic fluid monitoring system (OptiVol). On December 9, 2010, he suffered from general fatigue, but did not have any symptom due to VT. At midnight on December 15, the OptiVol alert due to severe increase of OptiVol fluid index was automatically transmitted. On the next day, we received the alert. In the transmitted data, we found that 85 episodes of sustained VT (mean HR 143 bpm) had occurred and antitachycardia pacing (ATP) was performed 243 times for the VT since December 9. He was diagnosed as HF due to electrical storm of slow VT and admitted emergently on the same day. He received medical treatment for HF and VT. Eventually, he underwent RFCA for VT because of resistance to medication. Finally, we succeeded in terminating the VT by RFCA and improving HF. He had asymptomatic electrical storm of VT, which developed into HF. In this case, the OptiVol alert provided the earlier detection of HF and consequently gave a chance to find out the asymptomatic electrical storm of slow VT resistant to repeated ATP.
著者
-
Tatsumi Hiroaki
the Department of Internal Medicine and Cardiology, Osaka City University Graduate School of Medicin
-
Maeda Keiko
The Department of Cardiovascular Internal Medicine, Osaka City University
-
Takagi Masahiko
The Department of Cardiovascular Internal Medicine, Osaka City University
-
Yoshiyama Minoru
The Department of Cardiovascular Internal Medicine, Osaka City University
-
Suzuki Kentaro
The Department of Cardiovascular Internal Medicine, Osaka City University
-
Tatsumi Hiroaki
The Department of Cardiovascular Internal Medicine, Osaka City University
関連論文
- The Simultaneous Assessment of Aortic Valve Area and Coronary Artery Stenosis Using 16-Slice Multidetector-Row Computed Tomography in Patients With Aortic Stenosis Comparison With Echocardiography
- OJ-129 Comparison of Daily Fluctuations in 12-Lead and Signal-Averaged Electrocardiogram between Spontaneous and Drug Induced Type 1 ECG in Brugada Syndrome (ECG / Body surface potential mapping / Holter(02)(A),Oral Presentation (Japanese),The 72nd Annual
- OE-019 Delayed Left Ventricular Untwisting Motion Detects Early Abnormality in Patients with Hypertension(Echo/Doppler-01, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- PJ-279 The Effects of Azithromycin Therapy on the Coronary Microcirculation in Patients With Coronary Artery Disease Assessed by Transthoracic Doppler Echocardiography(Infection/Inflammation/Immunity 3 (H) : PJ47)(Poster Session (Japanese))
- Detection of Coronary Artery Stenosis by Phasic Changes in Myocardial Blood Volume by Intravenous Myocardial Contrast Echocardiography in Humans
- Intrathoracic Fluid Monitoring System (OptiVol) Proved Useful for Earlier Detection of Heart Failure (HF) and Asymptomatic Electrical Storm of Slow VT: A Case Report