Digital Image Correlation Strain Analysis for the Study of Wrinkle Formation on Facial Skin
スポンサーリンク
概要
- 論文の詳細を見る
Strain measurements around the eye during the blink are performed for four human subjects in order to investigate the relationship between the wrinkle formation with aging and the strains by daily motion. In addition to the strain measurement, the moisture content, the flexibility and the elasticity of the skin surface are measured for investigating the skin condition. For observing the wrinkle formed on the facial skin, the replicas of the skin surfaces are also collected. Results show that the relationship between the wrinkle and the strain distribution at the inner corner of the eye is different from that at the corner of the eye. The results indicate that different methods for the corner of the eye and the inner corner of the eye are required for avoiding the wrinkle formation.
著者
-
Yoneyama Satoru
Department Of Cardiology Sekishinkai Sayama Hospital
-
ARIKAWA Shuichi
Department of Mechanical Engineering, Aoyama Gakuin University
-
MURAKAMI Motoko
Skincare Research Laboratory, Kanebo Cosmetics Inc.
-
MIURA Nagisa
Department of Mechanical Engineering, Aoyama Gakuin University
-
KOIKE Miyako
Skincare Research Laboratory, Kanebo Cosmetics Inc.
-
TANNO Osamu
Skincare Research Laboratory, Kanebo Cosmetics Inc.
関連論文
- OJ-031 Effectiveness of Reperfusion Therapy with a Distal Protection Device (PercuSurge) for Acute Myocardial Infarction(Acute Myocardial Infarction, Clinical (Diagnosis/Treatment) 1 (IHD) : OJ4)(Oral Presentation (Japanese))
- Rescue Percutaneous Thrombectomy System Provides Better Angiographic Coronary Flow and Does Not Increase the In-Hospital Cost in Patients With Acute Myocardial Infarction
- Thrombectomy with Rescue TM Catheter Prevents Left Ventricular Remodeling after Acute Anterior Wall Myocardial Infarction
- Predictors of Restenosis after Implantation of the Radius Stent
- Impact of Introduction of RescueTM Catheter to Treatment for Patients with Acute Myocardial Infarction
- Effectiveness of Thrombectomy with Rescue TM Catheter for Acute Myocardial Infarction
- Effectiveness of Thrombectomy With Rescue^ Catheter in Native coronary Arteries for Patients With Acute Myocardial Infarction
- Influence of Cyclic Loading on Inhomogeneous Deformation Behavior Arising in NiTi Shape Memory Alloy Plate
- Local Strain Distribution Arising in Shape Memory Alloy Composite Subjected to Thermal Loading
- Accurate Displacement Measurement by Correlation of Colored Random Patterns (Solid Mechanics and Material Engineering)
- 3D Surface Profile Measurement of Moving Object Using Linear Sensors(Optical Method 2)
- Photoelastic Analysis from a Single Image Using Elliptically Polarized Tricolored Light
- Evaluation of Time-Dependent Fracture Mechanics Parameters of a Moving Crack in a Viscoelastic Strip
- Inner Structure / Elastic Modulus Control of Micro Cantilever
- In-Plane Displacement Measurement Using Digital Image Correlation with Lens Distortion Correction
- Photoviscoelastic Stress and Strain Analysis around a Surface Groove under Rolling Contact Load
- Computing Strain Distributions from Measured Displacements on a Three-dimensional Surface
- Effect of Powder Contents on Viscoelastic Behavior of Glass Powder Filled Epoxy Resin
- Determining Stress Components from Isopachic Contours Using Airy Stress Function
- Bridge Deflection Measurement Using Digital Image Correlation with Camera Movement Correction
- Digital Image Correlation Strain Analysis for the Study of Wrinkle Formation on Facial Skin
- Development of High-Performance CFRP Flywheel
- Identification of Elasto-plastic Material Properties with Full-field Surface Displacement Measurements