Investigation of the Noise Effect on Tomographic Reconstructions for a Tangentially Viewing Vacuum Ultraviolet Imaging Diagnostic
スポンサーリンク
概要
- 論文の詳細を見る
Tomographic reconstruction for a tangentially viewing two-dimensional (2D) imaging system is studied. A method to calculate the geometry matrix in 2D tomography is introduced. An algorithm based on a Phillips-Tikhonov (P-T) type regularization method is investigated, and numerical tests using the P-T method are conducted with both tokamak and Heliotron configurations. The numerical tests show that the P-T method is not sensitive to the added noise levels and the emission profiles with higher mode numbers can be reconstructed with adequate resolution. The results indicate that this method is suitable for 2D tomographic reconstruction for a tangentially viewing vacuum ultraviolet telescope system.
- 社団法人 プラズマ・核融合学会の論文