Laser Absorption Spectroscopy for Diagnostics of a Neutral Helium Beam
スポンサーリンク
概要
- 論文の詳細を見る
The density resolution of a measurement system using laser absorption spectroscopy is evaluated in order to diagnose a fraction of metastable helium atoms (2 3S1) in a neutral helium beam. Experiments performed in a hollow cathode device show that the density resolution of the present system is about 5 × 1013 m-3 for a 1 m absorption length. Optimization of absorption scheme and improvements of signal detection are suggested, which shows that laser absorption spectroscopy is a promising diagnostic method for a neutral helium beam.
- 社団法人 プラズマ・核融合学会の論文
著者
-
KITAJIMA Sumio
Tohoku University, Sendai, Miyagi 980-8579, Japan
-
SASAO Mamiko
Tohoku University, Sendai, Miyagi 980-8579, Japan
-
OKAMOTO Atsushi
Tohoku University, Sendai, Miyagi 980-8579, Japan
-
SHINTO Katsuhiro
Tohoku University, Sendai, Miyagi 980-8579, Japan
関連論文
- Charge-Exchanged Beam Measurement by Using a Grid-Biased Faraday Cup
- Development of a helicon plasma source for the measurement of He* Component in a He0 Beam
- Laser Absorption Spectroscopy for Diagnostics of a Neutral Helium Beam