Evaluation of the Dependence of Tensile Strength and Fracture Strain of PLA Film on Machining Method
スポンサーリンク
概要
- 論文の詳細を見る
Some machining methods were used for making prototype of biodegradable stent made from poly lactic acid(PLA) film. Decrease of the tensile strength and fracture strain after machining was frequently observed. Therefore, in this paper, the tensile strengths of the films after machining were evaluated. The tensile strengths had maximum average value of 127.2MPa by the cutting plotter, and the minimum average value of 89.4MPa by the excimer laser. The machined surfaces were observed by scanning electron microscope. The machined surfaces by the cutting plotter and FHG -YAG laser were relative smooth. Those by the excimer laser and oxygen RIE, however, were rough. That by turret punch press was relative smooth and had flake-like burr. The surface roughness was related to the tensile strength, but not always related to fracture strain. It is supposed that surface irregularity caused the stress concentration and it reduced the tensile strength. On the other hand, it is supposed that the fracture strain was affected by the changes of property of surface and inner material, and they was caused by the shear deformation and the resolidification, crystallization and degradation induced by the processing heat.
著者
-
南 和幸
山口大学 大学院理工学研究科
-
佐藤 克也
徳島大学 大学院ソシオテクノサイエンス研究部
-
田中 孝之
山口大学 大学院医学系研究科 応用医工学系専攻
-
法村 一平
山口大学 大学院医学系研究科 応用医工学系専攻
関連論文
- 紫外レーザによる金属室温CVD
- Evaluation of the Dependence of Tensile Strength and Fracture Strain of PLA Film on Machining Method
- 高精度細胞伸展マイクロデバイスの開発と引張りを受ける細胞のその場観察
- 細胞圧縮刺激応答評価マイクロデバイスを用いた細胞応答のリアルタイム観察と評価
- 自己組織化マップを用いた聴覚刺激時における脳波に含まれる個人差に関する一考察