A sensitive atomic absorption spectrometric method for copper employing the direct introduction of chelating resin into a carbon tube atomizer.
スポンサーリンク
概要
- 論文の詳細を見る
A new and simple method for the determination of ppb levels of copper by electrothermal atomic absorption spectrometry was established. The main feature of the proposed method is that chelating resin, a preconcentration agent for copper, is introduced directly as a "resin-suspension" into the carbon tube atomizer without drying and weighing of the resin. To a 250 cm<SUP>3</SUP> sample solution containing up to 1.0 μg of copper, 0.10 g of chelating resin (below 400 mesh) is added, and the mixture is stirred for about 20 min. After the separation of the resin from the aqueous phase through a membrane filter, 5.0 cm<SUP>3</SUP> of resin-suspension is prepared by adding water to the resin. Then, 10 μdm<SUP>3</SUP> (resin: 0.2 mg) of the suspension is introduced into an atomizer, and the copper peak-height is measured under the optimum operating conditions. The calibration graph was linear over the concentration range from 0.1 ppb to 4.0 ppb of copper. The relative standard deviation was 2.3% from 10 repeated measurements; a mean value of 1.08 ppb copper was obtained for a sea water sample.
- 公益社団法人 日本化学会の論文
著者
-
Isozaki Akinori
Department Of Industrial Chemistry College Of Science And Technology Nihon University
-
UTSUMI Satori
Department of Industrial Chemistry, College of Science and Technology, Nihon University
-
Utsumi Satori
Department Of Industrial Chemistry College Of Science And Technology Nihon University
-
Soeda Naoki
Department of Industrial Chemistry, College of Science and Technology, Nihon University
関連論文
- Direct Simultaneous Determination for Ultratrace As, Se and Sb in River Water with Graphite-Furnace Atomic Absorpion Spectrometry by TiO_2-Slurry Sampling
- Direct Determination of Lead in Suspended Particulate Matter in Air by Tungsten Furnace-Atomic Absorption Spectrometry with a Punching Technique
- ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY FOR ALUMINUM BY DIRECT HEATING OF ALUMINUM-ADSORBED CHELATING RESIN
- Direct Determination of Iron in Silicon Carbide and Silicon Nitride by Electrothermal Atomic Absorption Spectrometry with Slurry-Introduction
- The Spectrophotometric Determination of Micro Amounts of Perchlorate by the Solvent-Extraction Method
- A sensitive atomic absorption spectrometric method for copper employing the direct introduction of chelating resin into a carbon tube atomizer.