A Case of the Abnormal Process of the Wire in the Fracture of the Femoral Neck
スポンサーリンク
概要
- 論文の詳細を見る
In multiple wiring of the fracture of the femoral neck, the operative involvement is very little. This method is easy, but the ability of this fixation is rather strong. We often use this method because of its aptitude to old persons.Recently we operated the peritrochanteric fracture of 84 year old female by this method, and the fixation was made with five Kirschner's wires. But while still in plaster, we found that one of the Kirschner's wires was in the pelvic cavity by roentgenography. By urgent laparatomy, we found the wire sticking in the uterus and pulled it out.Such a case was our first one, and in general very rare. In the inner fixation to the advanced osteporosis, we must the coiled wires or bend the end of the Kirschner's wires.
- 西日本整形・災害外科学会の論文
著者
関連論文
- A Case of the Abnormal Process of the Wire in the Fracture of the Femoral Neck
- The Results of Treatment of the Epidural Injection of Steroid Hormon for Low Back Pain