Our experience in the treatment of femoral neck fracture with Deyerle's device
スポンサーリンク
概要
- 論文の詳細を見る
Various methods of internal fixation for femoral neck fracture have been reported since Smith-Petersen's nail. Each of them has not only positive but also negative points.Recently, we have used Deyerle's device consisting of several pins and side plate in 9 patients. As a rule, full weight bearing is permitted immediately after operation. Pseudoarthrosis developed in one case, and aseptic necrosis of the femoral head in another.These 9 cases will be reviewed and the advantages or disadvantagest of his method will be discussed.