オキシラン酸素の定量法
スポンサーリンク
概要
- 論文の詳細を見る
Oxyrane oxygen of non-terminal epoxy compounds was determined with each method of hydrogen chloride-ether, dioxane and acetic acid solutions, and hydrogen bromide-acetic acid solution.<BR>It was found that water contained in the sample solution lowers the accuracy of determination.<BR>Hydrogen bromide-acetic acid solution method (Durbetaki's method) showed better accuracy among the above methods.<BR>Anhydrous hydrogen bromide-acetic acid solution was prepared easily by means of a procedure that hydrobromic acid was dissolved with acetic acid, and then equivalent amount of acetic anhydride to water was added into the solution.<BR>To increase the accuracy of determination, Durbetaki's method was modified as follows : In case standardization of hydrogen bromide-acetic acid solution, sodium carbonate was dissolved with 10ml of acetic acid, and then 10ml of benzene was added into the solution. The sample was dissolved with mixture of 10ml of benzene and 5ml of acetic acid.<BR>Interference for the determination was also investigated.
- 日本油化学会の論文
著者
関連論文
- 1,2-エピチオアルカンと酸無水物との反応
- 高級脂肪酸およびその誘導体のエポキシ化合物に関する研究 (第3報) : 過酢酸による不飽和脂肪酸のエポキシ化の速度
- 高級脂肪酸およびその誘導体のエポキシ化合物に関する研究 (第2報) : エポキシステアリン酸より酢酸塩によるエポキシステアリン酸塩の生成
- 有機過酸によるβ-エレオステアリン酸およびβ-エレオステアリン酸メチルの酸化
- オゾンによる有機化合物の酸化
- 1,2-エピチオアルカンの同定と定量
- オレフィン系化合物へのラジカル付加
- オキシラン酸素の定量法