アルミニウム合金中のスズのポーラログラフ法による定量
スポンサーリンク
概要
- 論文の詳細を見る
A method of determining 0.010.5% of tin in secondary aluminum alloys for die casting was investigated, and the following procedure was established.<BR>One gram of sample is taken up with hydrochloric acid and hydrogen peroxide, and tin is extracted into MIBK from 6<I>N</I> HCl medium. It is then backextracted into water, and is concentrated with a little hydrochloric acid. After the co-existing ferric ion is reduced by the addition of ascorbic acid, tin is determined by d. c. polarography in the presence of 3.5<I>N</I> HCl-5×10<SUP>-4</SUP> <I>M</I> tetraphenylarsonium chloride and 10v/v% ethanol as the supporting electrolyte. The half-wave potential is-0.45 V <I>vs</I>. Hg pool.<BR>It takes 80 minutes for a determination, and the precision of this method is approximately 2% as the coefficient of variation for aluminum alloys containing 0.2% tin.
- 社団法人 日本分析化学会の論文
著者
関連論文
- 快削性アルミニウム合金中のビスマス,鉛のポーラログラフによる定量
- 非鉄金属分析 (分析化学進歩総説1967年版)
- アルミニウム合金中のスズのポーラログラフ法による定量
- アルミニウム-ケイ素 銅系アルミニウム合金中の銅の迅速定量