STUDY OF SKIN CONTAMINATION WITH RADIOACTIVE SUBSTANCES A ROLE OF HORNY LAYER OF SKIN (PART 1)
スポンサーリンク
概要
- 論文の詳細を見る
We carried out a role of horny layer of skin as for skin contamination. In the case of the skin with horny layer, the internal permeance of <SUP>131</SUP>I-Na was slow and slight. In the case of the skin without horny layer, we had better think that the internal permeance of <SUP>131</SUP>I-Na was rapidly and revealed the internal contamination as almost same as in the case of venous injection of <SUP>131</SUP>I-Na. For the prevention of the internal contamination, it was necessary that horny layer of skin was intact. In the case of the normal skin with horny layer, the permeance of <SUP>131</SUP>I-Na was slow by 20 min. after application and then the contamination of <SUP>131</SUP>I-Na should be removed within 20 min. after application. Out of the radioactive substances, iodine, anion, has the easy permeability and volatility. So we have pay expressly attention to handling it comparing with the other radioactive substances.
- 久留米大学医学部 The Kurume Medical Journal 編集部の論文
著者
-
UMEZAKI Noriyoshi
Radioisotope Institute for Basic and Clinical Medicine, Kurume University School of Medicine
-
Kawakami Katsuyuki
Department Of Rheumatology And Clinical Immunology Hirakata Hospital Kansai Medical University
-
KOGA HISAMITSU
Department of Radiology, Yanagawa Public Hospital
-
YANO KIYOSHI
Department of Radiology, Yanagawa Public Hospital
-
YANO KIYOSHI
Department of Radiology Kurume University School of Medicine
関連論文
- A case of dual ectopic thyroid accompanied by positive antithyroid antibodies
- Indium-111 antimyosin monoclonal antibody Fab imaging in patients with cardiomyopathy
- Determining the breast-feeding interruption schedule after administration of ^I-iodide
- Isolated Tuberculous Liver Abscess Invading the Abdominal Wall : Report of a Case
- A case of rheumatoid pericarditis associated with a high IL-6 titer in the pericardial fluid and tocilizumab treatment
- Computed color radiography expressing an energy dependence of X-ray attenuation coefficients.
- Use of a gadolinium filter on an X-ray contrast examination.
- CLINICAL EVALUATION OF RI-ANGIOSCANNOGRAPHY WITH 131I-MAA ON LUNG CANCER
- Clinical evaluation of computed tomography in esophageal cancer.
- TUMOR SCINTIGRAM WITH 201 T1
- WAVY PERIODICAL RESPIRATION BY ROENTGEN IRRADIATION
- DYNAMIC AND QUANTITATIVE STUDY OF CISTERNOGRAPHY WITH 169 Yb-DTPA
- Study of skin contamination with radioactive substances. 2. Influence of pH.:INFLUENCE OF pH
- SIGNAL/BACKGROUND RATIO IN SCINTIGRAM
- The attempt on iso-image in kidney scan with 99m Tc DTPA.
- EVALUATION OF THE RENOSCINTIORAM AND ENOORAM WITH 99 m Tc-DTPA IN THE CLINICAL FINDINGS
- Study of skin contamination with radioactive substances. 3. About the contamination removal reagents.:ABOUT THE CONTAMINATION REMOVAL REAGENTS
- THE COMPARATIVE STUDY ON NUCLIDES FOR TUMOR SCANAGENTS (PART 2)
- STUDY OF SKIN CONTAMINATION WITH RADIOACTIVE SUBSTANCES A ROLE OF HORNY LAYER OF SKIN (PART 1)
- THE COMPARATIVE STUDY ON NUCLIDES FOR TUMOR SCANAGENTS (PART 1)