A Stress Analysis of the Proximal Tibia after Insertion of the Endprosthesis
スポンサーリンク
概要
- 論文の詳細を見る
Detailed investigation for the local stress increment at the fixation post bottom of an artificial knee joint was performed by two-dimensional finite element method. A strain measurement was also conducted by wire strain gauges on a cancellous bone with a special method. It was made clear that a curvature with a certain extent of radius was necessary for the corner of a fixation post and application of acrylic cement with a certain extent of thickness (3 mm≥) was effective for stress relaxation, and that an optimum value (10-110 GPa) existed for elastic modulus of bone cement.
著者
-
伊勢亀 冨士朗
Department of Orthopedic Surgery, School of Medicine Keio University
-
水野 正夫
Faculty of Science and Technology, Department of Mechanical Engineering Keio University
-
戸松 泰介
Department of Orthopedic Surgery, School of Medicine Tokai University
-
高橋 邦弘
Faculty of Science and Technology, Department of Mechanical Engineering Keio University
-
丹羽 悦夫
Tsurumi Factory, Tokyo Gas Co. Ltd.