Comparison of gas membrane separation cascades using conventional separation cell and two-unit separation cells.
スポンサーリンク
概要
- 論文の詳細を見る
The adoption of two-unit separation cells in radioactive rare gas membrane separa-tion equipment enhances the separation factor, but increases the required membrane area and compressive power. An analytical economic evaluation was undertaken to compare the conventional separation cell with the two-unit separation cells, adopting as parameters the number of cascade stages, the membrane area and the operating power requirements.<BR>This paper describes the models used for evaluating the separation performance and the economics of cascade embodying these different concepts of separation cell taken up for study, and the results obtained for the individual concepts are mutually compared.<BR>It proved that, in respect of the number required of cascade stages, of operating power requirements and of the annual expenditure, better performance could always be expected of the two-unit separation cells as compared with the conventional separation cell, at least in the range of parameters adopted in this study. As regards the minimum membrane area, the conventional separation cell and the series-type separation cell yielded almost the same values, with the parallel-type separation cell falling somewhat behind.
- 一般社団法人 日本原子力学会の論文
著者
-
OHNO Masayoshi
Nuclear and Electrical Engineering Laboratory, Toshiba Research and Development Center, Tokyo Shibaura Electric Co., Ltd.
-
OZAKI Osamu
Nuclear and Electrical Engineering Laboratory, Toshiba Research and Development Center, Toshiba Corporation
-
MIYAUCHI Terukatsu
Department of Chemical Engineering, Tokyo University
-
MORISUE Tetsuo
Nuclear and Electrical Engineering Laboratory, Toshiba Research and Development Center, Tokyo Shibaura Electric Co., Ltd.
-
MIYAUCHI TERUKATSU
Department of Chemical Engineering, University of Tokyo
-
OZAKI Osamu
Nuclear and Electrical Engineering Laboratory, Toshiba Research and Development Center, Tokyo Shibaura Electric Co., Ltd.
関連論文
- Effect of the cascade operation of enzymes in packed bed immobilized enzyme reactors.
- Radioactive rare gas separation performance of a two-unit series-type separation cell.
- FLUID AND PARTICLE DISPERSION IN FLUID-BED REACTORS:Experimental Investigations by Steady Heat-transfer and Steady Back-mixing of Adsorptive Gases
- Reaction by the enzyme entrapped by UF membrane with acceleration of mass transfer by pressure swing.
- Comparison of gas membrane separation cascades using conventional separation cell and two-unit separation cells.
- Effects of radiation on gas permselective membranes.
- Computational studies of a chromatographic moving-bed reactor for consecutive and reversible reactions.
- RATE OF SULFONATION OF ALPHA-OLEF1N BY GASEOUS SO3 USING PULSE METHOD
- Gas separation performance of tapered cascade with membrane.
- LIQUID FILM COEFFICIENT OF MASS TRANSFER IN LOW PÉCLET NUMBER REGION FOR SPHERE PACKED BEDS
- LIQUID FILM COEFFICIENT OF MASS TRANSFER ON FREE LIQUID SURFACE
- GENERALIZED EQUATION OF CONTINUITY AND ITS APPLICATIONS TO HETEROGENEOUS SYSTEMS
- Effect of compaction on conversions in immobilized enzyme packed columns.
- Correction of the temperature difference between bubble and emulsion phases and revised gas exchange rate in fluidized beds.
- ANSWER TO THE LETTER BY LISA AND BARILE
- Chemical forms of uranium in artificial seawater.
- Stability of chemical reaction in fluid catalytic reactors.