Drop formation characteristics in high speed agitation of centrifugal extractor.
スポンサーリンク
概要
- 論文の詳細を見る
For the solvent extraction of reprocessing plant, mixer-settler, pulsed column are op-erated and centrifugal extractor is expected to be used. Mixer-settler has the defect of long contact time. It comes out to cause the solvent damage by radiation in FBR fuel re-processing. In order to escape from the damage, pulse column and centrifugal extractor should be used for FBR spent fuel. However, the characteristics in centrifugal extractor have not yet been fully analyzed, while those of mixer-settler are advanced much. There-fore, the agitation experiment was made to find out the difference of drop formation be-tween mixer-settler and centrifugal extractor. From the results, the average drop diameter is proportional to Weber number to the power of -0.58, when the contact time is long. However, the agitation velocity did not affect the average drop size, when the contact time is less than 11.3 s.
- 一般社団法人 日本原子力学会の論文
著者
-
FUMOTO Hiromichi
Department of Nuclear Engineering, Faculty of Engineering, University of Tokyo
-
KIYOSE Ryohei
Department of Nuclear Engineering, Faculty of Engineering, University of Tokyo
関連論文
- Interface characteristics in settler of centrifugal extractor.
- Drop formation characteristics in high speed agitation of centrifugal extractor.
- Analysis of optimization problem of advanced energy technology introduction.
- Design of environmental monitoring system of nuclear facility based on a method of pattern recognition.