Determination of Large Negative Reactivity by Integral Versions of Various Experimental Methods
スポンサーリンク
概要
- 論文の詳細を見る
The large negative reactivity is measured in Semi-Homogeneous Experimental facility (SHE). Experimental methods are Sjostrands pulsed neutron, source multiplication and rod drop methods beside revised King-Simmons pulsed neutron methods. Neutron detectors are placed at various points in the core region for multi-points measurement.<BR>Usual one-point reactor model analysis resulted in the reactivity values, strongly de-pendent on the detector position with the increase of subcriticality. In addition, disagree-ments between the used experimental methods are also pointed out.<BR>In order to overcome these difficulties due to the spatial higher harmonics and the kinetic distortion in the neutron flux distribution, an integral version analysis is applied, in which use is made of multi-points reactor model. In the analysis, space integration of the neutron counts obtained throughout the core region is made with weights of the ad-joint function of fast neutrons, calculated using the two- or three-dimensional diffusion code. The negative reactivity values determined by the integral version analysis agreed well with each other within the uncertainty of 5% in the reactivity range down to -50 dollars.<BR>It is concluded that all the experimental methods are adequate for precise determination of the large negative reactivity of reactor provided that the integral version analysis is utilized or that correction is made for the change of the neutron generation time using precise calculation.
著者
-
KANEKO Yoshihiko
Japan Atomic Energy Research Institute
-
AKINO Fujiyoshi
Japan Atomic Energy Research Institute
-
YASUDA Hideshi
Japan Atomic Energy Research Institute
関連論文
- Determination of Large Negative Reactivity by Integral Versions of Various Experimental Methods
- Analysis of reactivity coefficients of Chernobyl reactor by cell calculation.
- Evaluation of delayed neutron data for thermal fission of U-235 based on integral experiments at semi-homogeneous experiment.
- Measurements of doppler effect of coated particle fuel rod in SHE-14 core using sample heating device.
- Measurement of Prompt Neutron Decay Constant in Delayed Critical State of Heavily Reflected Reactor
- Measurement of Neutron Slowing Down Time in Graphite
- Determination of Neutron Multiplication, (II):Experiments and Analysis
- Determination of Neutron Multiplication, (I):Concept
- A Pulsed Neutron Source for Thermal Reactor Physics