In-Situ Measurement of Fission Product Plateout in In-Pile Gas Loop Using Portable Ge(Li) Gamma-Ray Spectrometer
スポンサーリンク
概要
- 論文の詳細を見る
A nondestructive and quantitative method of measuring fission products deposited on inside surface of the primary duct has been developed. A portable Ge (Li) detector with a lead collimator was used for the external scanning of γ-rays emitted from the fission product plateout in the duct. Upon termination of the first irradiation cycle for the coated particle fuels in the high temperature in-pile gas loop OGL-1 installed in JMTR (Japan Material Testing Reactor), in-situ measurements of the plateout were carried out by the above method at different points in the primary system. Identified nuclides in the measured r-ray spectra were 131I, 133I, 95Zr, 95Nb, 137Cs, 110mAg, <SUP>99</SUP>Mo, <SUP>140</SUP>La, <SUP>60</SUP>Co, <SUP>58</SUP>Co, <SUP>54</SUP>Mn, <SUP>51</SUP>Cr, <SUP>65</SUP>Zn, <SUP>59</SUP>Fe, <SUP>122</SUP>Sb, <SUP>124</SUP>Sb, <SUP>182</SUP>Ta, <SUP>181</SUP>Hf, <SUP>22</SUP>Na and <SUP>46</SUP>Sc. The plateout densities of these nuclides were obtained using conversion coefficients determined by detector calibration and calculation, which were from 10<SUP>-5</SUP> to 10<SUP>-2</SUP> μCi/cm<SUP>2</SUP>. It was shown clearly by the experiment that the present measuring method using an in-situ r-ray spectrometer is useful in the studies of fission product plateout in the primary cooling system of a high temperature gas cooled reactor.
著者
-
KATAGIRI Masaki
Japan Atomic Energy Research Institute
-
Katagiri Masaki
Japan Atomic Energy Agency
-
WAKAYAMA Naoaki
Japan Atomic Energy Research Institute
-
TERADA Hiromi
Japan Atomic Energy Research Institute
-
TAKAHASHI Hidetake
Japan Atomic Energy Research Institute
関連論文
- Spatial response analysis on superconducting X-ray detectors by Low Temperature Scanning Synchrotron Microscopy
- Large-Area Tunnel Junction Exhibiting Two Operating Modes for X-ray Detection
- Detection of Synchrotron Radiation by Nb-Based Superconducting Tunnel Junctions
- Prompt In-Line Diagnosis of Single Bunch Transverse Profiles and Energy Spectra for Laser-Accelerated Ions
- In-Situ Measurement of Fission Product Plateout in In-Pile Gas Loop Using Portable Ge(Li) Gamma-Ray Spectrometer
- Evaluation of Water Distribution in a Small-Sized PEFC by Neutron Radiography
- High-temperature characteristics of Pt-Mo alloy thermocouple for in-core temperature measurements in very high temperature gas-cooled reactor.
- Environmental gamma-ray exposure rates measured by in-situ Ge(Li) spectrometer.