Core restraint analysis for 75MW power ascension tests of experimental fast reactor "JOYO".
スポンサーリンク
概要
- 論文の詳細を見る
In the "JOYO" initial power ascension tests to 75 MW, unexpected large negative power coefficients were observed during ascension to new power levels beyond 50 MW, which results in approximately a 400 permanent loss in reactivity. <BR>This anomaly was studied from the viewpoint of radial dimensional change in the core using a three-dimensional structural analysis code along with a whole-core thermal-hydraulic analysis code. Conclusions drawn from the study can be summarized as follows :(1) The absolute value of the power coefficient increases sharply beyond the 50 MW power level due to the outward leaning and thermal bowing of core elements, but the calculated increase in the coefficient is less than 20% of the observed value.<BR>(2) At most, an 80 permanent loss in reactivity is caused by this outward leaning, which is 20% of the observed value. <BR>(3) These results confirm that the radial dimensional change can not be the main cause for the power coefficient anomaly.
- 一般社団法人 日本原子力学会の論文
著者
-
Miki Kazuyoshi
Energy Reseasrch Laboratory Hitachi Ltd.
-
INOUE Kotaro
Energy Research Laboratory, Hitachi Ltd
-
INOUE Kotaro
Energy Research Laboratory, Hitachi Ltd.
-
SANDA Toshio
Energy Research Laboratory, Hitachi Ltd.
-
YAMASHITA Yoshioki
Oarai Engineering Center, Power Reactor and Nuclear Fuel Development Corp.
関連論文
- A DOMAIN DECOMPOSITION AND OVERLAPPING TECHNIQUE METHOD FOR 3D LARGE SCALE NUMERICAL SIMULATION
- Simple method for evaluating mesh size effects in control rod worth analysis.
- Program control of current build-up in tokamak.
- Core restraint analysis for 75MW power ascension tests of experimental fast reactor "JOYO".
- Calculation model for predicting power distribution in fast reactors.