Preliminary experimental study for cryogenic distillation column with small inner diameter, (I)
スポンサーリンク
概要
- 論文の詳細を見る
A preliminary experimental study was performed by using a cryogenic distillation column which has a small inner diameter (2cm). The column separated N<SUB>2</SUB> and Ar at a total reflux operation mode. The experimental column simulates adequately some significant fea-tures of a hydrogen isotope distillation column. A significant result obtained is that the mesh of the wire holding the packings was required to be as large as possible and conically-shaped for avoiding the flooding. The dynamic column behavior predicted by computer-aided simulation is in very close agreement with the experimental observation. The HETP value was measured for Dixon Ring under a variety of vapor flow rates within the column. The measured value is approximately 5.5 cm. The over-all HETP value is almost independent of the vapor flow rate. However, if the vapor flow rate is excessively small, the HETP value for the upper half of the column differs slightly from that for the lower half.
- 一般社団法人 日本原子力学会の論文
著者
-
YAMANISHI Toshihiko
Division of Thermonuclear Fusion Research, Japan Atomic Energy Research Institute
-
KINOSHITA Masahiro
Division of Thermonuclear Fusion Research, Japan Atomic Energy Research Institute
関連論文
- Computer-Aided Simulation Procedure for Water Distillation Columns
- A Wide-Area Sensor Network Based on Fiber Optic Power Supply