Determination of melting point of mixed-oxide fuel irradiated in fast breeder reactor.
スポンサーリンク
概要
- 論文の詳細を見る
For UO<SUB>2</SUB> and (U, Pu)O<SUB>2</SUB>, many workers<SUP>(1)</SUP> have determined melting points by use of a filament in situ measurement. However, it is indicated that temperature measurement for this technique may be influenced by the high vapor pressure of the specimen at high temperature and the oxygen-to-metal ratio may also change during heating of the filament<SUP>(2)(4)</SUP>. Thereafter, a thermal arrest technique has been newly developed<SUP>(2)</SUP> using specimen enclosed in a sealed tungsten capsule to maintain the stoichiometric composition at the melting.
- 一般社団法人 日本原子力学会の論文
著者
-
YAMANOUCHI Sadamu
Fuel and Material Division,Power Reactor and Nuclear Fuel Development Corp.
-
TACHIBANA Toshimichi
Fuel and Material Division,Power Reactor and Nuclear Fuel Development Corp.
-
OHMORI Tsuyoshi
Fuel and Material Division,Power Reactor and Nuclear Fuel Development Corp.
-
ITAKI Toshiyuki
Fuel and Material Division,Power Reactor and Nuclear Fuel Development Corp.