Development of Pt-Mo Alloy Thermocouples for Incore Temperature Measurement in HTGRs.
スポンサーリンク
概要
- 論文の詳細を見る
The Pt-Mo alloy thermocouples with element wires of Pt-5%Mo and Pt-0.1%Mo were developed for incore temperature measurements at a maximum temperature of 1, 200°C for a long term and of 1, 350°C for a short term in VHTRs. The thermocouples were tested at high temperature conditions of 1, 0001, 400°C in an outpile electric furnace and in an incore capsule in the JMTR. The total thermal neutron fluence irradiated was 8.1×10<SUP>20</SUP> n/cm<SUP>2</SUP>. The changes in their electromotive forces due to those exposures to high temperatures and radiation in the reactor core were evaluated to be less than ±2%. This meets the specifications that is required for the incore temperature measurements in VHTRs. Hence, the developed thermocouples can be used also in the incore temperature measurement in advanced type HTGRs and in incore irradiation experiments in the HTTR, in future.
- 一般社団法人 日本原子力学会の論文
著者
-
YAMADA Masaharu
Department of Reactor Engineering, Tokai Research Establishment, Japan Atomic Energy Research Institute
-
ARA Katsuyuki
Department of Reactor Engineering, Tokai Research Establishment, Japan Atomic Energy Research Institute