Etude sur la Combination des Reservoirs et des Colonnes de Diffusion Thermique
スポンサーリンク
概要
- 論文の詳細を見る
The heat siphon has long been in general use for the purpose of enriching the isotopes present in a reservoir into a thermal diffusion column. K. Clusius and H.H. Buhler developed an alternative method, the gas oscillator, which they utilized as a gas connecting method.<BR>We analyzed both methods mathematically, resulting in the conclusion that the flow rate ¦σR¦ (g/sec) of the heat siphon and of the gas oscillator should have a value ranging from 3H to 5H, and that the period of the gas oscillator 2T(sec) has little influence on the enrichment process, which permits us to choose a value convenient for operation.
- 一般社団法人 日本原子力学会の論文
著者
関連論文
- Estimation de I'Influence du Mode d'Ecoulement du Gaz sur le Facteur de Separation d'une Colonne de Diffusion Thermique