Measurement of release rate of NaCl aerosol from a fume hood.
スポンサーリンク
概要
- 論文の詳細を見る
Concentration of NaCl aerosol released from a fume hood to the work place was measured at face velocities of fume hood up to 0.5m/sec. Influence on the release rate of aerosol was investigated, i. e. the movement of a worker in front of the fume hood and the flow rate of room air supply. Release of the aerosol was detected in work place when fume hood face velocity was lower than 0.4m/sec. The concentration of aerosol released to the work place increased with a decrease in the face velocity. On the other hand, the release was not detected at face velocity 0.5m/sec in any working condition, where the concentration in the air was less than 8×10-12μg/cm3 per dispersion rate (μg/min), as the detection limit. This value was 1/4, 000 of the concentration which was estimated assuming that 1/10 of the aerosol quantity in the fume hood was released.
- 日本保健物理学会の論文
著者
-
小林 誠
日本原子力研究所東海研究所保健物理部
-
宍戸 宣仁
日本原子力研究所東海研究所保健物理部
-
松下 紘三
日本原子力研究所東海研究所保健物理部
-
山本 峯澄
日本原子力研究所東海研究所保健物理部
-
山本 峯澄
日本原子力研究所保健物理安全管理部
関連論文
- RI使用施設等の解体・廃止に関する二, 三の知見
- グローブボックス解体時における空気中放射能濃度の管理
- コンクリートケーブの放射能漏洩試験
- Measurement of release rate of NaCl aerosol from a fume hood.
- Airborne Fission Products Released during Cutting of Irradiation Fuels
- Notes from Radiation Workers (Vol. 18, No. 1)
- 環境モニタリング
- Measurement of Tritium in Exhausted Air Using Silicagel