Development of Sensors for On-Line Monitoring of Nonmetallic Impurities in Liquid Sodium
スポンサーリンク
概要
- 論文の詳細を見る
Sensors for on-line monitoring of hydrogen and carbon in sodium and hydrogen in argon cover gas circuits over sodium have been developed. The performance of these sensors in fast breeder test reactor (FBTR) and large sodium facilities is evaluated. A sensor for monitoring oxygen in sodium is under development. The in-sodium electrochemical hydrogen sensors are found to detect about 10 ppb increase in hydrogen concentration over a background of 50 ppb. The cover gas hydrogen monitoring sensor system is found to sense hydrogen down to 2 vppm in argon over sodium systems. Electrochemical carbon sensors are capable of detecting down to 1 ppm of carbon in sodium.
著者
-
GANESAN Rajesh
Liquid Metals and Structural Chemistry Division, Chemistry Group, Indira Gandhi Centre for Atomic Re
-
JAYARAMAN Venkataraman
Liquid Metals and Structural Chemistry Division, Chemistry Group, Indira Gandhi Centre for Atomic Re
-
RAJAN BABU
Liquid Metals and Structural Chemistry Division, Chemistry Group, Indira Gandhi Centre for Atomic Re
-
SRIDHARAN Ragavachary
Liquid Metals and Structural Chemistry Division, Chemistry Group, Indira Gandhi Centre for Atomic Re
-
GNANASEKARAN Thiagarajan
Liquid Metals and Structural Chemistry Division, Chemistry Group, Indira Gandhi Centre for Atomic Re
関連論文
- Development of Sensors for On-Line Monitoring of Nonmetallic Impurities in Liquid Sodium
- Development of Sensors for On-Line Monitoring of Nonmetallic Impurities in Liquid Sodium