Depth Scaling of Solid Phantom for Intensity Modulated Radiotherapy Beams
スポンサーリンク
概要
- 論文の詳細を見る
To reduce the uncertainty of absorbed dose for high energy photon beams, water has been chosen as a reference material by the dosimetry protocols. However, solid phantoms are used as media for absolute dose verification of intensity modulated radiotherapy (IMRT). For the absorbed dose measurement, the fluence scaling factor is used for converting an ionization chamber reading in a solid phantom to absorbed dose to water. Furthermore the depth scaling factor is indispensable in determining the fluence scaling factor. For IMRT beams, a photon energy spectrum is varied by transmitting through a multileaf collimator and attenuating in media. However, the effects of spectral variations on depth scaling have not been clarified yet. In this study, variations of photon energy spectra were determined using the EGS Monte Carlo simulation. The depth scaling factors for commercially available solid phantoms were determined from effective mass attenuation coefficients using photon energy spectra. The results clarified the effect of spectral variation on the depth scaling and produced an accurate scaling method for IMRT beams.
- 日本放射線影響学会の論文
著者
-
Tohyama Naoki
Department Of Radiological Sciences Tokyo Metropolitan University Of Health Sciences
-
Myojoyama Atsushi
Dept. Of Radiology Tokyo Metropolitan Univ. Of Health Sciences:crest Jst
-
Myojoyama Atsushi
Graduate School Of Health Sciences Tokyo Metropolitan University
-
Saitoh Hidetoshi
Graduate School Of Health Sciences Tokyo Metropolitan University
-
FUJITA Yukio
Graduate School of Health Sciences, Tokyo Metropolitan University
-
Tohyama Naoki
Chiba Cancer Center
関連論文
- Interface software for DOSXYZnrc Monte Carlo dose evaluation on a commercial radiation treatment planning system
- Effects of Density Changes in the Chest on Lung Stereotactic Radiotherapy
- 262 Develompent of an accurate dose calculation system for remotely supporting radiotherapy(Bases of radiotherapy, Abstracts of the 46th Annual Meeting of the Japan Radiation Research Society)
- Construction of DICOM Server using Oracle and CTN Software
- Distribution of Scattered Radiation from Patient in CT Diagnosis
- Bremsstrahlung and Photoneutron Leakage from Steel Shielding Board Impinged by 12-24 MeV Electrons Beams
- Depth Scaling of Solid Phantom for Intensity Modulated Radiotherapy Beams
- Depth Scaling of Solid Phantom for Intensity Modulated Radiotherapy Beams
- Relation between Lineal Energy Distribution and Relative Biological Effectiveness for Photon Beams according to the Microdosimetric Kinetic Model