Evaluation of a Compact Sampler Designed for the Simultaneous Collection of Atmospheric Polycyclic Aromatic Hydrocarbons in Size-fractionated Particulate Matter and the Gaseous Phase
スポンサーリンク
概要
- 論文の詳細を見る
A compact sampler consisting of a three-stage cascade impactor and a holder for polyurethane form (PUF) plugs was designed for the simultaneous collection of atmospheric polycyclic aromatic hydrocarbons (PAHs) in fine particles and the gaseous phase. To evaluate its collection efficiency, air was passed through a quartz-fiber filter (QFF) spiked with 28 authentic PAHs and then through cleaned PUF plugs and backup filters for 24hr in the dark at a constant room temperature (20 or 35°C). PAHs retained on the QFF and those trapped within PUF plugs and backup filters were separately determined. We observed no obvious difference in recoveries between 20 and 35°C except for benzo[a]anthracene (BaA) and triphenylene+chrysene. Most of the PAHs with low molecular weight (166-202) vaporised from the QFF and were trapped in the PUF plugs and backup filters at recoveries of 42-108%, while those with high molecular weight (≥252) were largely retained on the QFF (recoveries of 75-114%). BaA and triphenylene+chrysene (molecular weight=228) were largely retained on the QFF at 20°C (recoveries of ≥84%), but at 35°C the recovery values decreased to levels similar to those trapped with PUF plugs and backup filters (recoveries of 40-56%). The proposed sampler was applied in an investigation of ambient PAHs at a roadside site in a heavy-traffic area in Osaka, Japan, during August 2006 and February 2007.
著者
-
Kishida Masao
Research Institute of Environment, Agriculture and Fisheries, Osaka Prefectural Government
-
Okamoto Takahide
College of Engineering, Osaka Institute of Technology
-
Fujimori Keiichi
College of Engineering, Osaka Institute of Technology
-
Imamura Kiyoshi
Research Institute of Environment, Agriculture and Fisheries, Osaka Prefectural Government
-
Nishimura Yasuki
Customer Support of Osaka, GL Science, Inc.
-
Shibutani Yasuhiko
College of Engineering, Osaka Institute of Technology
-
Bandow Hiroshi
Graduate School of Engineering, Osaka Prefecture University
-
Okamoto Takahide
Coll. Of Engineering Osaka Inst. Of Technol.
-
藤森 啓一
大阪工大 工
-
Fujimori Keiichi
Department Of Applied Chemistry Faculty Of Engineering Osaka Institute Of Technology
-
Nishimura Yasuki
Customer Support Of Osaka Gl Sci. Inc.
-
Shibutani Yasuhiko
College Of Engineering Osaka Institute Of Technology
-
Fujimori Keiichi
Coll. Of Engineering Osaka Inst. Of Technol.
-
Bandow Hiroshi
Graduate School Of Engineer. Osaka Prefect. Univ.
-
Fujimori Keiichi
Department Of Applied Materials Science College Of Engineering Osaka Prefecture University
関連論文
- Evaluation of a Compact Sampler Designed for the Simultaneous Collection of Atmospheric Polycyclic Aromatic Hydrocarbons in Size-fractionated Particulate Matter and the Gaseous Phase
- ジオキシム型シッフ塩基-ポリ塩化ビニル感応膜の銀イオン選択性評価
- Temporal Change in Atmospheric Polycyclic Aromatic Hydrocarbons in Particulate Matter from an Urban Location of Osaka, Japan : Estimation of Causes of a Significant Increase in their Concentrations in the Winter Season
- Potentiometric SCN-Selectivity of Polymer Membranes with Fixed Organotin Compounds
- Chemiluminescence Method with Potassium Permanganate for the Determination of Organic Pollutants in Seawater
- Anion Selectivities of Dibutyltin Dihalides as Neutral Carriers for Ion-Selective Electrodes
- Additive-Salt Effect on Low Detection Limit and Slope Sensitivity in Response of Potassium- and Sodium-Selective Neutral Carrier Based Electrodes and Their Liquid-Membrane Based Ion-Sensitive Field-Effect Transistor
- Pyrazole-Containing Crown Ethers as Ionophores for NH_4^+-Selective Electrodes
- Chiral Bis(12-crown-4)-based Electrodes for Sodium Ion
- Effects of α-Substituents on Ion Selectivity of Bis(12-crown-4-methyl)Malonates as Neutral Carriers for Sodium Ion-Selective Electrodes
- Effects of Additive Salts on Electrochemical Characteristics of Neutral Carrier Based Electrodes
- Potentiometric Performance of Silver Ion-Selective Electrodes Based on Tridentate Schiff Base Derivatives
- Oxidative Reaction of Thiosulfate with Hydrogen Peroxide by Freezing
- Trance Level Determination of Low-Molecular-Weight Alcohols in Aqueous Samples Based on Alkyl Nitrite Formation and Gas Chromatography
- Measurement of Dissolved Oxygen Based on Enhanced Cerium(IV) Chemiluminescence
- 1L21 Flow Analysis Method for Determining the Concentration of Atmospheric Alcohols Using the Nitrite Formation Reaction
- DECREASE OF SOLUTES IN THE AQUEOUS SOLUTION IN THE FREEZING PROCESS (2)
- CHEMICAL REACTIONS IN POLYCRYSTALLINE ICE
- DECREASE OF SOLUTE IN THE AQUEOUS SOLUTION IN THE FREEZING PROCESS
- Mechanism of Chemiluminescence Reaction between Hypobromite and Ammonia or Urea
- Decomposition of Geosmin in Aqueous Solution by Sonication
- A Gaseous Nitric Acid Analyzer for the Remote Atmosphere Based on the Scrubber Difference/NO-Ozone Chemiluminescence Method
- 2C1128 Continuous monitoring of total odd reactive nitrogen (NO_y) and total nitrates in Fukue Island, Nagasaki, Japan : Their concentration level and temporal variability compared with simultaneous data of those entities at Cape Hedo, Okinawa(1 Space-5 E
- Mesomorphic Effect of Discotic-type Liquid-crystalline Compounds as Neutral Carriers on Potentiometric Ion-sensing Membranes
- Ion-sensing Behavior of Ion-selective Electrodes Based on 5, 10, 15, 20-Tetrakis (4-n-Dodecylphenyl) porphyrin
- Determination of Sulfide with Acidic Permanganate Chemiluminescence for Development of Deep-sea in-situ Analyzers
- 六座配位子シッフ塩基-ニッケル(II)錯体を用いるポリ塩化ビニル含浸型 : 過塩素酸イオンセンサー
- P-59 Influence of adding salt on ultrasonic atomization in ethanol-water solution(Poster Presentations)
- P-58 Effect of reactor size on the sonochemical degradation rates(Poster Presentations)
- P-18 Inactivation of Microorganisms by Ultrasonic Irradiation : Comparison between the Effects of Shock Wave with H_2O_2(Poster Presentations)
- P-54 Sonochemical decomposition of butyric acid in water(Poster Presentations)