Verification of BWR Turbine Skyshine Dose with the MCNP5 Code Based on an Experiment Made at SHIMANE Nuclear Power Station
スポンサーリンク
概要
- 論文の詳細を見る
We measured the skyshine dose from turbine buildings at Shimane Nuclear Power Station Unit 1 (NS-1) and Unit 2 (NS-2), and then compared it with the dose calculated with the Monte Carlo transport code MCNP5. The skyshine dose values calculated with the MCNP5 code agreed with the experimental data within a factor of 2.8, when the roof of the turbine building was precisely modeled. We concluded that our MCNP5 calculation was valid for BWR turbine skyshine dose evaluation.
著者
-
TAYAMA Ryuichi
Hitachi-GE Nuclear Energy, Ltd.
-
WAKASUGI Kenichi
Hitachi-GE Nuclear Energy, Ltd.
-
KAWANAKA Ikunori
The Chugoku Electric Power Co., Inc.
-
KADOTA Yoshinobu
The Chugoku Electric Power Co., Inc.
-
MURAKAMI Yasuhiro
The Chugoku Electric Power Co., Inc.