Artifacts of Vena Cava Filters ex vivo on MR Angiography
スポンサーリンク
概要
- 論文の詳細を見る
We evaluated magnetic susceptibility artifacts of nine types of vena cava filters in MR angiography (MRA) at 1.0T ex vivo in order to assess the filters compatibility with MRA. Each filter (tulip filter, tulip MReye filter, stainless Greenfield filter, titanium Greenfield filter, TrapEase filter, Simon filter, LGM Vena-Tech filter, Antheor temporary filter, and Birds nest filter) was inserted into an acrylic tube (20 or 25 mm in diameter, 15 or 30 cm in length). Gd-DTPA was poured into each tube at a concentration of 1/500 and each was placed in a water-filled container for imaging. We evaluated artifacts of the filters according to the following criteria: signal void beyond the tube, 3+; signal void within the tube but at more than one-half the diameter of the tube, 2+; and signal void within the tube but at less than one-half the diameter of the tube, 1+. We evaluated artifacts originating at the tip, intermediate portion, and distal end of the filters. We judged the artifacts as follows: tulip (3+, 3+, 3+); tulip MReye (2+, 1+, 1+); stainless Greenfield (2+, 1+, 2+); titanium Greenfield (1+, 1+, 1+); TrapEase (1+, 2+, 1+); Simon (2+, 2+, 1+); LGM (2+, 2+, 1+); Antheor (2+, 2+, 2+); and Birds nest (3+, 3+, 3+). The numbers in parentheses refer to the degree of signal void at the tip, intermediate portion, and distal end of the filter, respectively. The tulip filter and Birds nest filter made of 304 stainless steel caused extensive signal voids beyond the areas defined by the filters. The signal voids in the remaining seven filters were limited to within the tube. We concluded that seven of the nine filters were compatible with MRA ex vivo.
- 日本磁気共鳴医学会の論文
- 2003-07-01
著者
-
Sugimoto Hideharu
Department Of Radiology Jichi Medical School
-
Honda Minoru
Department Of Radiology Showa University Hospital
-
Obuchi Masao
Department Of Radiology Showa University Fujigaoka Hospital
-
SUGIMOTO Hideharu
Department of Radiology, Jichi Medical School
関連論文
- Distortion of anterior airway anatomy during laryngoscopy with the GlideScope videolaryngoscope
- Precision of the gallbladder ejection fraction obtained with Tc-99m-pyridoxyl-5-methyl-tryptophan (^Tc-PMT) hepatobiliary scintigraphy as compared with the contraction ratio in three-dimensional computed tomography
- Usefulness of rate of increase in SPECT counts in one-day method of N-isopropyl-4-iodoamphetamine [^I] SPECT studies at rest and after acetazolamide challenge using a method for estimating time-dependent distribution at rest
- LONG-TERM RESULTS OF SURGERY FOR SUPERIOR OBLIQUE PALSY
- RESULTS OF SURGERY FOR PARALYTIC ESOTROPIA DUE TO ABDUCENS PALSY
- Response of early active rheumatoid arthritis to tumor necrosis factor inhibitors : evaluation by magnetic resonance imaging
- The role of Gd-enhanced three-dimensional MRI fast low-angle shot (FLASH) in the evaluation of symptomatic lumbosacral nerve roots
- Moderately T_2-weighted Images Obtained with the Single-Shot Fast Spin-Echo Technique : Differentiating between Malignant and Benign Urinary Obstructions
- Preliminary examination to determine the suitable contrast material injection protocol for CT angiography of the pelvis and lower extremities with a multidetector row helical scanner
- Artifacts of Vena Cava Filters ex vivo on MR Angiography
- VIRTUAL ENTEROSCOPY USING AIR AS THE CONTRAST MATERIAL : A PRELIMINARY FEASIBILITY STUDY
- Sonographic findings of Sister Mary Joseph's nodule from ovarian cancer
- SISCOM technique with a variable Z score improves detectability of focal cortical dysplasia : a comparative study with MRI
- Cardiovascular Pathology in Spontaneously Hypertensive Rats Chronically Exposed to Combined Restraint and Electric Stimulation