Reduction of False Positives in a CAD System for GGO Nodule Detection by Means of Neural Classification and CT Coronal View Examination
スポンサーリンク
概要
- 論文の詳細を見る
In this paper, we investigate a procedure for decreasing the number of false positive findings in a reported Computer Aided Diagnosis (CAD) system for the detection of Ground Glass Opacity (GGO) nodules in chest Computed Tomography (CT) images. The proposed procedure consists of two main stages. The first stage is the application of a Radial Basis Function (RBF) neural network on the CT images using a sliding sub-image window scanned over the region of interest (ROI). The RBF network was trained using both, GGO nodule and false positive samples in order to gain the ability to differentiate between both findings. The second stage involves the examination of coronal CT images to confirm the existence of GGO candidates in the transaxial CT images based on the fact that nodular candidates tend to appear similarly in both sections. The algorithm was applied on 2100 slice images containing 27 GGO nodules representing the majority of the typical findings found in the real clinical practice. It succeeded to achieve a detection sensitivity of 96.3% with False Positive (FP) rate of 0.147 FP/slice in case of using the RBF network alone and further improved to 0.06 FP/slice when applying the RBF network together with the coronal images examination, which proves the potential effectiveness of the proposed algorithm.
- 社団法人 電気学会の論文
著者
-
NITTA Norihisa
Department of Radiology, Shiga University of Medical Science
-
Bastawrous Hany
Electrical Engineering Department, Ritsumeikan University
-
Tsudagawa Masaru
Electrical Engineering Department, Ritsumeikan University
関連論文
- Cisplatin-conjugated Gelpart : initial study in vitro
- Pulmonary infarction associated with bronchogenic carcinoma
- Laser-guided computed tomography puncture system : simulation experiments using artificial phantom lesions and preliminary clinical experience
- Assessment of diaphragmatic motion after lung resection using magnetic resonance imaging
- Multidetector-Row Computed Tomography Coronary Angiography : Optimization of Image Reconstruction Phase According to the Heart Rate
- A case of lymphangiomatosis
- A case of Ewing's sarcoma in the chest wall
- Uitra Low-dose Helical CT of the Chest: Evaluation in Clinical Cases
- 大型ウサギの血管系インターベンショナルラジオロジーに対する有用性の検討
- Reduction of False Positives in a CAD System for GGO Nodule Detection by Means of Neural Classification and CT Coronal View Examination
- CAD System for Pulmonary Nodule Detection Using Gabor Filtering and Template Matching (特集:電気関係学会関西支部連合大会)
- Renal Segmental Hypoplasia, Ask-Upmark Kidney, in a Patient with Adult-onset Hypertension