Fabrication and measurements of direct contact type RF MEMS switch
スポンサーリンク
概要
- 論文の詳細を見る
This paper reports on the fabrication and measurements of a direct contact type RF MEMS switch. The switch is driven by the electrostatic force making the pass-through state with metal-to-metal direct contact. The actuation pad is connected with support beams to reduce switch deformation and increase contact force. The insertion loss and isolation of the switch have been measured and compared with the characteristics of the switch without support beams. The switch shows the isolation of 15.5dB and the insertion loss of 0.34dB at 50GHz with an applied DC bias of 35V. The switching time is measured to be 5.1µs. Power handling capability and reliability of the fabricated switch have been discussed.
著者
-
Park Jae-hyoung
Department Of Environmental Engineering Pukyong National University
-
Park Jae-Hyoung
Department of Physics, Ewha Womans University
関連論文
- Photodegradation of Toluene and Xylene by Fluidized Bed Gaseous System with TiO_2/SiO_2 Photocatalysts
- Investigation of Similar and Dissimilar Metal Contacts for Reliable Radio Frequency Micorelectromechanical Switches