Tensile and Anti-Spalling Properties of Direct Sprayed ECC
スポンサーリンク
概要
- 論文の詳細を見る
The use of Engineered Cementitious Composite (ECC), which has metal-like deformation and crack opening restriction ability, as a retrofit material for structures, has been the subject of high expectations. For this application, the direct spray method has been commonly accepted. This study focused on experimentally clarifying the fundamental properties of direct sprayed ECC containing high-performance polyvinyl alcohol fibers. The experiments that were performed demonstrated that direct sprayed ECC was successfully processed and showed pseudo-strain hardening performance comparable to that of traditionally cast ECC reported in the literature. Furthermore, test results simulating concrete cover cracking due to re-bar corrosion demonstrated that direct sprayed ECC has significant potential to prolong service life of R/C members in a heavy chloride environment.
著者
-
Hiraishi Masanori
Materials and Life Cycle Engineering Group, Kajima Technical Research Institute
-
Kanda Tetsushi
Building Construction and Materials Group, Kajima Technical Research Institute
-
Saito Tadashi
Industrial Goods Development Dept., Kuraray
-
Sakata Noboru
Materials and Life Cycle Engineering Group, Kajima Technical Research Institute
関連論文
- Tensile and Anti-Spalling Properties of Direct Sprayed ECC
- Study on Evaluation Method for PVA Fiber Distribution in Engineered Cementitious Composite