Field Tests of Wind Turbine Unit with Tandem Wind Rotors and Double Rotational Armatures
スポンサーリンク
概要
- 論文の詳細を見る
This paper discusses the field tests of the wind turbine unit, in which the front and the rear wind rotors drive the inner and the outer armatures of the synchronous generator. The wind rotors were designed conveniently by the traditional procedure for the single wind rotor, where the diameters of the front and the rear wind rotors are 2 m and 1.33 m. The tests were done on a pick-up type truck driven straightly at constant speed. The rotational torque of the unit is directly proportional to the induced electric current irrespective of the rotational speeds of the wind rotors, while the induced voltage is proportional to the relative rotational speed. The performance of the unit is significantly affected not only by the wind velocity, but also by the blade setting angles of both wind rotors and the applied load especially at lower wind velocity.
- 社団法人日本機械学会の論文
著者
-
Kanemoto Toshiaki
Graduate School Of Engineering Kyushu Inst. Of Technol.
-
Galal Ahmed
Graduate School Of Engineering Kyushu Institute Of Technology
-
GALAL Ahmed
Graduate School of Engineering, Kyushu Institute of Technology
関連論文
- Development of Intelligent Wind Turbine Unit with Tandem Wind Rotors and Double Rotational Armatures (2nd Report, Characteristics of Tandem Wind Rotors)
- Development of Intelligent Wind Turbine Generator with Tandem Wind Rotors and Double Rotational Armatures : 1st Report, Superior Operation of Tandem Wind Rotors
- Field Tests of Wind Turbine Unit with Tandem Wind Rotors and Double Rotational Armatures