Designed-seamless irradiation technique for extended whole mediastinal proton-beam irradiation for esophageal cancer
スポンサーリンク
概要
- 論文の詳細を見る
BackgroundProton-beam therapy (PBT) provides therapeutic advantages over conformal x-ray therapy in sparing organs at risk when treating esophageal cancer because of the fundamental physical dose distribution of the proton-beam. However, cases with extended esophageal lesions are difficult to treat with conventional PBT with a single isocentric field, as the length of the planning target volume (PTV) is longer than the available PBT field size in many facilities. In this study, the feasibility of a practical technique to effectively match PBT fields for esophageal cancer with a larger regional field beyond the available PBT field size was investigated.MethodsTwenty esophageal cancer patients with a larger regional field than the available PBT single-field size (15 cm in our facility) were analyzed. The PTV was divided into two sections to be covered by a single PBT field. Subsequently, each PTV isocenter was aligned in a cranial-caudal (CC) axis to rule out any influence by the movement of the treatment couch in anterior-posterior and left-right directions. To obtain the appropriate dose distributions, a designed-seamless irradiation technique (D-SLIT) was proposed. This technique requires the following two adjustments: (A) blocking a part of the PTV by multi-leaf collimator(s) (MLCs); and (B) fine-tuning the isocenter distance by the half-width of the MLC leaf (2.5 mm in our facility). After these steps, the inferior border of the cranial field was designed to match the superior border of the caudal field. Dose distributions along the CC axis around the field junction were evaluated by the treatment-planning system. Dose profiles were validated with imaging plates in all cases.ResultsThe average and standard deviation of minimum dose, maximum dose, and dose range between maximum and minimum doses around the field junction by the treatment-planning system were 95.9 ± 3.2%, 105.3 ± 4.1%, and 9.4 ± 5.2%. The dose profile validated by the imaging plate correlated with the results of the treatment-planning system in each case, with an error range within 4.3%.ConclusionsDose distributions around the field junction were applied using D-SLIT. D-SLIT can be a useful treatment strategy for PBT of extended esophageal cancer.
著者
関連論文
- 小児腫瘍に対する陽子線治療の実現可能性評価
- 85歳以上の超高齢者悪性腫瘍に対する放射線治療の検討
- 筑波大学陽子線医学研究利用センターにおける新陽子線施設での初期臨床経験
- 5.肺・胸膜・肝内転移を繰り返し,腎障害・心筋障害も来たした,2002年登録肝芽腫難治症例における治療経過(続報) : CPT-11,陽子線照射,ラジオ波焼灼(RFA)の効果(日本小児肝癌スタディグループ研究会2006,研究会)
- がんの放射線治療のなかでの陽子線治療の位置付け (特集 第39回放射線による制癌シンポジウム--基礎と臨床との対話 21世紀の放射線による先端医療と研究のさらなる発展を目指して) -- (IMRT・IGRT vs 粒子線治療 あなたならどちらを選びますか?)
- 治療談話会記録 粒子線治療装置の新展開
- 巨大肝細胞癌に対する陽子線治療
- 筑波大学陽子線医学利用研究センターにおける陽子線治療の臨床試験報告
- 3.SLIT法を用いた食道癌同時併用化学陽子線治療の初期成績
- Verification of beam delivery using fibrosis after proton beam irradiation to the lung tumor
- Designed-seamless irradiation technique for extended whole mediastinal proton-beam irradiation for esophageal cancer
- 筑波大学陽子線医学研究利用センターにおける新陽子線施設での初期臨床経験