腋窩神経の走行を推定するために, 神経に伴行する後上腕回旋動脈の位置をポケット型超音波血流検知器を用いて測定することの有効性の研究
スポンサーリンク
概要
- 論文の詳細を見る
In our previous study, we determined the method that the course of the axillary nerve was projected on the skin covering the deltoid muscle of a cadaver in order to safely administer intramuscular injection in the deltoid muscle. In this study, we examined whether this method could be adapted to 7 living bodies by detecting blood flow of the posterior humeral circumflex artery which runs along with the axillary nerve using a handheld ultrasound blood flowmeter. We determined that the blood flow could be detected along the course of the axillary nerve predicted in a living body. Although the number of living bodies examined in this series was limited, this study indicates that the method of determining the course of the axillary nerve in the cadaver can be adapted to the living body and checking the course ofthe posterior humeral circumflex artery by the ultrasound blood flowmeter is useful to ascertain the course of the axillary nerve. 我々は、三角筋筋肉内注射部位に関する解剖体を用いた先行研究において、腋窩神経損傷を避けるために、同神経の位置を体表面から相対的に決定する方法を明らかにした。今回の研究では、先行研究と同一の方法によって7 名の被験者において腋窩神経の走行部位を推定し、その部位に同神経に伴行する後上腕回旋動脈の血流音を聴取できるかについて超音波血流検知器を用いて検討した。その結果、腋窩神経が走行すると推定した部位において後上腕回旋動脈の血流を聴取することができた。これらの結果より、先行研究における腋窩神経走行部位の相対的な決定方法が生体にも応用可能であること、また、超音波血流検知器を用いて後上腕回旋動脈の血流音を確認することによって腋窩神経走行部位をより確実に決定できることが示唆された。