509 非常用ガスタービン発電機の耐震性の確証
スポンサーリンク
概要
- 論文の詳細を見る
The emergency gas turbine generator of lOOOkVA will be set up in MOX fuel fabrication facilities in Japan Nuclear Fuel Ltd. In order to confirm the integrity of the generator at earthquake, vibration test was carried out by using three dimension shaking table. The seismic wave for the test was settled considering the dynamic seismic force calculated by performing dynamic analysis using the basic earthquake ground motion for Class S equipment. As a result of test, no abnormal event was observed in various testing conditions. Also, the acceleration in which the function of the generator had been confirmed was identified.
- 一般社団法人日本機械学会の論文