E101 Heat transport directional reversal within the regenerator of a coaxial travelling wave thermoacoustic heat pump
スポンサーリンク
概要
- 論文の詳細を見る
We have constructed a travelling wave thermoacoustic heat pump using a coaxial configuration with the regenerator positioned in the annulus. It was discovered that within the frequencies ranging from 100Hz to 400Hz a frequency dependent directional reversal of heat transport within the regenerator occurred. By decomposing the acoustic wave within the annulus for the tested frequencies, it was revealed that the cause of the reversal was due to the change of the acoustic field in regards to the magnitudes of the positive and negative direction travelling waves.