Demonstration of pneumococcal capsule under immunoelectron microscopy
スポンサーリンク
概要
- 論文の詳細を見る
It is challenging to demonstrate the capsule of Streptococcus pneumoniae (S. pneumoniae) under immunoelectron microscopy because of the thick mucopeptide cell wall hampering proper fixation. A novel rapid freeze fixation method was established to observe the capsule of S. pneumoniae. A strain of serotype 3 of S. pneumoniae isolate was analyzed after rapid freezing. An ethanol freezing-substitution fixing method was applied and immunohistochemical staining with osmium tetroxide was tested. The capsule was confirmed using the serotype 3 specific polyclonal antibodies labeled with colloidal gold particles. To the best of our knowledge, this is the first report of S. pneumoniae capsule by immunoelectron microscope.
著者
-
ICHINOSE Akitoyo
Electron Microscope Laboratory
-
Ichinose Akitoyo/
Electron Microscopy Shop Central Laboratory Institute Of Tropical Medicine Nagasaki University/depar
関連論文
- Role of Lipooligosaccharide in the Attachment of Moraxella catarrhalis to Human Pharyngeal Epithelial Cells
- Demonstration of pneumococcal capsule under immunoelectron microscopy