F209 EFFECTS OF LEAKAGE COOLING ON IP ROTOR DISC AND ROOT IN 600MW STEAM TURBINE(Steam Turbine-3)
スポンサーリンク
概要
- 論文の詳細を見る
Numerical simulation is performed on the first two stages of IP cylinder of a 600MW steam turbine using CFD and CHT methods. Cooling effects of HP cylinder leakage steam on IP cylinder rotor is investigated and flow behavior of the leakage steam in cooling passages is studied, with configurations of seals, root bottom gaps and diaphragm-to-disc gaps included. Efficient cooling effects are achieved on the rotor and blade root of the first stage, with highest temperature decrease being up to 90K. No obvious cooling effects are found on the second stage rotor blade and rotor disc. Maximum temperature of rotor groove for first and second stage appears at trailing and leading side of its meshing surface with root flat, with value being 796K and 803K separately, which are 41K and 34K lower than the temperature of IP cylinder fresh mean steam.
- 一般社団法人日本機械学会の論文
- 2009-11-16
著者
-
Yang Hong
Shanghai Electric Power Generation Equipment Co. Ltd Turbine Works
-
Yang Hong
Shanghai Electric Power Generation Equipment Co. Ltd
-
YANG Jiandao
Shanghai Electric Power Generation Equipment Co., Ltd
-
QI Mingxu
School of Mechanical and Vehicular Engineering, Beijing Institute of Technology
-
ZHOU Daiwei
Shanghai Electric Power Generation Equipment Co., Ltd
-
Qi Mingxu
School Of Mechanical And Vehicular Engineering Beijing Institute Of Technology
-
Zhou Daiwei
Shanghai Electric Power Generation Equipment Co. Ltd
-
Yang Jiandao
Shanghai Electric Power Generation Equipment Co. Ltd
関連論文
- F209 EFFECTS OF LEAKAGE COOLING ON IP ROTOR DISC AND ROOT IN 600MW STEAM TURBINE(Steam Turbine-3)
- F214 INFLUENCE OF THE BLADE SHROUD GAP TO THE NATURAL FREQUENCY OF THE INTERLOCKED TURBINE BLADE(Steam Turbine-5)
- Dielectric Breakdown Properties of Zr-Rich Lead Zirconate Titanate Ceramics
- Dielectric Breakdown Properties of Zr-Rich Lead Zirconate Titanate Ceramics