A211 Experimental and Numerical Investigations of the Double-Jet Film Cooling Technology(Gas Turbine-6)
スポンサーリンク
概要
- 論文の詳細を見る
The Double-Jet Film-Cooling (DJFC) technology is invented by the authors and comprises a significant enhancement of the adiabatic film-cooling effectiveness due to the formation of anti-kidney vortices. The DJFC technology places a second ejection hole with compound angle in a double-hole arrangement downstream the first hole. The second hole creates a second jet with another dominating vortex rotating in opposite direction to the first one and then combines both jets to one jet (or double jet). The basic applicability and function of the DJFC technology has been proven by the numerical studies and testing in a test rig. The comparison of the experimental results of the adiabatic film cooling effectiveness to the numerical results for the same blowing ratio (e. g. M=0.5; M = (p * C)_c/(p * C)_h) shows qualitatively similar distributions. However, the experimental results show enhanced mixing-out of the cooling air and, thus, the experimental values of the adiabatic film cooling effectiveness are lower compared to the numerical values.
- 一般社団法人日本機械学会の論文
- 2009-11-16
著者
-
KAZARI Masahide
Kawasaki Heavy Industries, Ltd.
-
Bohn Dieter
Institute of Steam and Gasturbine, Aachen University
-
Kusterer Karsten
B&B-AGEMA GmbH
-
Elyas Anas
B&b-agema Gmbh
-
Bohn Dieter
Institute Of Steam And Gas Turbines Rwth Aachen University
-
Bohn Dieter
Institute Of Steam And Gas Turbines Aachen University Of Technology
-
Karsten Kusterer
B&b-agema Gmbh
-
ELYAS Anas
B&B-AGEMA GmbH
-
SUGIMOTO Takao
Kawasaki Heavy Industries, LTD., Gas Turbine & Machinery Company
-
TANAKA Ryozo
Kawasaki Heavy Industries, LTD., Gas Turbine & Machinery Company
-
Tanaka Ryozo
Kawasaki Heavy Industries Ltd. Gas Turbine & Machinery Company
-
Sugimoto Takao
Kawasaki Heavy Industries Ltd. Gas Turbine & Machinery Company
-
Sugimoto Takao
Kawasaki Heavy Industries Ltd.
-
Kazari Masahide
Kawasaki Heavy Industries Ltd. Technical Institute
-
Kazari Masahide
Kawasaki Heavy Industries Ltd.
関連論文
- D105 Development of an Efficient Small-scale Distributed Power Generation System Using Gasification of Woody Biomass(Biomass-2)
- 冷却翼開発における熱流体連成シミュレーションの適用とパイロメータによる実機での温度計測
- トランスピレーション冷却を有するタービン翼前縁周りの流れの数値解析 : 第1報,基本パラメータに対する諸特性(流体工学,流体機械)
- TS-82 Influence of Endwall Phenomena on Leading Edge Ejection(Session C-10 Turbine Cooling 2)
- A211 Experimental and Numerical Investigations of the Double-Jet Film Cooling Technology(Gas Turbine-6)
- Kawasaki M7A-02 Industrial Gas Turbine(New Models and Products)
- C103 CONJUGATE HEAT TRANSFER, INTERNAL FLOW, AND EXTERNAL FLOW ANALYSES FOR A FILM-COOLED BLADE
- Kawasaki M7A-01 Gas Turbine(New Models and Products)
- TS-77 Numerical Conjugate Flow and Heat Transfer Investigation of a Transonic Convection-Cooled Turbine Guide Vane with Different Thermal Barrier Coatings(Session C-9 Turbine Cooling 1)