F104 PEFCスタック故障影響評価に向けた出力分析および冷却孔閉塞時における基礎的検討(OS5 水素・燃料電池)
スポンサーリンク
概要
- 論文の詳細を見る
Polymer electrolyte fuel cell (PEFC) has advantages because of less environmental impact and high system efficiency. It is expected to use many applications such as fuel cell vehicles, residential fuel cell systems. However, there are many technical problems to overcome for the practical use of fuel cells. In particular, it is important to improve the system reliability and the stack failure diagnosis. In this study, PEFC stack performances and effects of cooling failure were investigated. From the result, voltage deviations were calculated in consideration of the Nernst loss caused by the hydrogen partial pressure loss. From the results of a cooling failure test, the plugged cell temperature increased by 8.65℃ at 33 A. The voltage of plugged cell increased on the cooling failure test, though the stack voltage dropped.
- 一般社団法人日本機械学会の論文
- 2009-06-28
著者
関連論文
- セル電圧分布を用いたPEFCスタック内部状態推定と局所セル性能低下による影響検討
- 磁場測定による固体高分子形燃料電池スタック内における電流分布の検討
- 磁気センサを用いた太陽電池面内の電流分布測定手法の開発
- 太陽電池モジュール出力特性のばらつきによる太陽電池アレイ定格出力への影響
- A209 太陽光発電システムの不具合検出におけるバイパスダイオードの発熱と通電の評価(太陽光と温度差発電・熱回収,OS2 自然エネルギー)
- バイパスダイオードの発熱状況による太陽光発電システム不具合評価
- 出力解析による太陽光発電システムの性能評価手法の検討
- 端子箱温度に着目した簡易的な結晶系Si太陽電池の不具合検出方法
- 太陽光発電システムにおけるバイパスダイオードの動作評価の検討
- F104 PEFCスタック故障影響評価に向けた出力分析および冷却孔閉塞時における基礎的検討(OS5 水素・燃料電池)
- セミナーの概要(「エネルギー学」部会セミナー報告:「原子力災害,地球温暖化,原油価格高騰を乗り越える日本のエネルギー政策)
- セミナーの概要