2〜50MeV電子に対する制動輻射断面積の計算と遮蔽計算への適用の検討
スポンサーリンク
概要
- 論文の詳細を見る
Differencial bremsstrahlung cross sections of lead, iron, and carbon for electrons whose kinetic energies were 50, 10, and 2 MeV, and total numbre of bremsstrahlung photons emitted when those electrons were stopped in those materials were calculated. Electron energy and atomic number dependence of the bremsstrahlung spectra and their absolute values were investigated. As formulas of the cross section calculation, Sauter's and Shiff's were choosed for a good agreement with the experimental values of gold, aluminum, and beryllium. Fortunately their formulas have simple forms. As a result, it was found as a noteworthy fact that the total number of bremsstrahlung photons emitted when 50 MeV electrons were stopped in lead and carbon were approximately same, so that the bremsstrahlung due to high energy electrons is not negligble even in a light material. The method of adopting the bremsstrahlung in Monte Carlo radiation shielding program was also discussed in this study.
- 独立行政法人 海上技術安全研究所の論文
- 1987-01-30
著者
関連論文
- 10,30keV単色X線に対するLiFTLDの線量応答 : LET依存性(東海支所,所外発表論文等概要)
- 銅、銀、または金を後方にもつTLDの20-40keV単一エネルギー光子に対する応答(原子力技術部,所外発表論文等概要)
- 放射光アンジオグラフィのための非均質ファントム内吸収線量分布測定及び解析(原子力技術部,所外発表論文等概要)
- モンテカルロコードMORSEによる制動幅射を含むガンマ線の輸送計算(原子力技術部,所外発表論文等概要)
- 最適遮蔽配列を構築するためのモンテカルロシミュレーション(原子力技術部,所外発表論文等概要)
- 鉄-ポリエチレン遮蔽体系の全線量率低減化のための最適配列(原子力技術部,所外発表論文等概要)
- 鉄-ポリエチレン遮蔽体系の中性子線量率に対する最適配列(原子力技術部,所外発表論文等概要)
- 使用済核燃料輸送船における線量率測定と中性子のモンテカルロ解析(原子力技術部,所外発表論文等概要)
- ポリエチレンロッド+鉄平板体系中性子遮蔽実験(原子力技術部,所外発表論文等概要)
- 2〜50MeV電子に対する制動輻射断面積の計算と遮蔽計算への適用の検討
- 鉄-ポリエチレン遮蔽体系における中性子線量率の変化とモンテカルロ解析(原子力技術部,所外発表論文等概要)
- 使用済核燃料輸送船内の線量率測定とモンテカルロ分割結合計算による解析(原子力船部,所外発表論文等概要)